{"title":"Temperature Calibrators","description":"\u003cp data-start=\"260\" data-end=\"737\"\u003eCalibrators are essential for verifying the accuracy of temperature sensors, transmitters and measurement systems. IOThrifty offers a range of high-performance temperature calibrators including block calibrators, fluidized baths and temperature simulators. These tools support quality control, maintenance programs and traceable calibration in both industrial and laboratory environments.\u003c\/p\u003e\n\u003cp data-start=\"739\" data-end=\"1174\"\u003e\u003cstrong data-start=\"739\" data-end=\"762\"\u003eWhy Use Calibrators\u003c\/strong\u003e\u003cbr data-start=\"762\" data-end=\"765\"\u003eAccurate temperature measurement is critical for process reliability, safety and compliance. Calibrators ensure that RTDs, thermocouples, transmitters, controllers and data acquisition systems read correctly. Whether you are conducting routine maintenance checks or performing controlled laboratory calibration, these instruments provide the stability and precision needed for confidence in your measurements.\u003c\/p\u003e\n\u003cp data-start=\"1176\" data-end=\"1744\"\u003e\u003cstrong data-start=\"1176\" data-end=\"1238\"\u003eBlock Calibrators – Stable, Controlled Temperature Sources\u003c\/strong\u003e\u003cbr data-start=\"1238\" data-end=\"1241\"\u003eBlock calibrators provide a highly stable and uniform temperature environment for verifying thermocouples and RTDs. IOThrifty block calibrators are designed for durability and consistent performance, making them well suited for maintenance shops, calibration departments and industrial environments where accurate sensor verification is needed. While not handheld devices, they are engineered for ease of use, straightforward operation and dependable thermal performance across a wide temperature range.\u003c\/p\u003e\n\u003cp data-start=\"1746\" data-end=\"2263\"\u003e\u003cstrong data-start=\"1746\" data-end=\"1816\"\u003eFluidized Baths – Exceptional Uniformity for Lab-Grade Calibration\u003c\/strong\u003e\u003cbr data-start=\"1816\" data-end=\"1819\"\u003eFluidized bath calibrators provide superior temperature uniformity and repeatability, making them ideal for metrology labs and high-precision calibration applications. These systems maintain extremely consistent thermal conditions throughout the bath, ensuring highly accurate results for sensors that require tight tolerances or traceable calibration. Fluidized baths excel in demanding environments where precision and stability are critical.\u003c\/p\u003e\n\u003cp data-start=\"2265\" data-end=\"2664\"\u003e\u003cstrong data-start=\"2265\" data-end=\"2324\"\u003eTemperature Simulators – Electrical Signal Verification\u003c\/strong\u003e\u003cbr data-start=\"2324\" data-end=\"2327\"\u003eTemperature simulators generate precise electrical outputs that mimic thermocouples or RTDs, allowing verification of transmitters, indicators, controllers and data loggers without applying actual heat. Simulators are excellent for troubleshooting, commissioning, functional checks and validating measurement systems at the signal level.\u003c\/p\u003e\n\u003cp data-start=\"2666\" data-end=\"2775\"\u003e\u003cstrong data-start=\"2666\" data-end=\"2682\"\u003eApplications\u003c\/strong\u003e\u003cbr data-start=\"2682\" data-end=\"2685\"\u003eCalibrators are used wherever accurate, consistent temperature measurement is essential.\u003c\/p\u003e\n\u003cul data-start=\"2776\" data-end=\"3146\"\u003e\n\u003cli data-start=\"2776\" data-end=\"2838\"\u003e\n\u003cp data-start=\"2778\" data-end=\"2838\"\u003eVerifying RTDs, thermocouples and temperature transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2839\" data-end=\"2929\"\u003e\n\u003cp data-start=\"2841\" data-end=\"2929\"\u003ePerforming routine maintenance and calibration in industrial plants or service centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2930\" data-end=\"3004\"\u003e\n\u003cp data-start=\"2932\" data-end=\"3004\"\u003eConducting high-accuracy laboratory calibration with traceable results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3005\" data-end=\"3069\"\u003e\n\u003cp data-start=\"3007\" data-end=\"3069\"\u003eTesting controllers, indicators and data acquisition systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3070\" data-end=\"3146\"\u003e\n\u003cp data-start=\"3072\" data-end=\"3146\"\u003eSupporting quality assurance, regulatory compliance and audit requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3148\" data-end=\"3625\"\u003e\u003cstrong data-start=\"3148\" data-end=\"3172\"\u003eWhy Choose IOThrifty\u003c\/strong\u003e\u003cbr data-start=\"3172\" data-end=\"3175\"\u003eIOThrifty offers calibrators selected for precision, stability and reliability. Our block calibrators provide consistent temperature sources for sensor verification, fluidized baths deliver lab-grade performance for demanding calibrations and temperature simulators add valuable functionality for signal testing. With expert guidance and dependable equipment, IOThrifty helps ensure your temperature measurement systems stay accurate and trustworthy.\u003c\/p\u003e","products":[{"product_id":"accurate-thermal-systems-thermcal400-temperature-calbrators","title":"ThermCal400 Block Temperature Calibrator","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLaboratory Performance at an Economical Price\u003c\/li\u003e\n\u003cli\u003eLightweight \u0026amp; Portable for Use in the Field\u003c\/li\u003e\n\u003cli\u003eRemovable Probe Inserts for Flexibility and Many Probe Sizes (one multiwell insert that accepts 1\/8\", 3\/16\", 1\/4\", 5\/16\" \u0026amp; 3\/8\" diameter probes)\u003c\/li\u003e\n\u003cli\u003eAdjustable Ramp Rate for Testing Thermal Switches\u003c\/li\u003e\n\u003cli\u003eFast Heat up \u0026amp; Stabilization\u003c\/li\u003e\n\u003cli\u003eOperates Ambient +5\u003cspan class=\"font3\" id=\"degree-symbol\"\u003e°\u003c\/span\u003eC to 455\u003cspan class=\"font3\" id=\"degree-symbol\"\u003e°\u003c\/span\u003eC\/752°F\u003c\/li\u003e\n\u003cli\u003eRS485 Interface for PC Connection\u003c\/li\u003e\n\u003cli\u003eCE, Cal Certificate, Designed \u0026amp; Mfg in USA\u003c\/li\u003e\n\u003cli\u003eCalibrated to °C, contact iothrifty.com for °F calibration (no charge)\u003c\/li\u003e\n\u003cli\u003eEverything you need to operate the ThermCal400 is included with the unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith over 25 years experience of designing, manufacturing and supporting Dry Block Temperature Calibrators, Accurate Thermal Systems, has developed two units that offer outstanding performance, features and value that are unmatched. These units have a small footprint, fast heat up and cool down and are light weight for both field and laboratory use. Unlike many competing lower cost models that only offer a fixed block, these units accept inserts for probe size flexibility in addition to fixed holes.\u003c\/p\u003e\n\u003cp\u003eThe ThermCal400 controller offers  large, bright and easy to read display. This controller has advanced 5 zone PID control for optimum performance and adjustable ramp rates for proper testing of thermal switches. The unit is switchable between F and C along with the ability to easily adjust unit calibration using your own  temperature standards.\u003c\/p\u003e\n\u003cp\u003eIndependent limit control is incorporated into the units to prevent operation and\/or fault conditions above 425C. A cooling fan keeps the internal components and controller cool at all operating temperatures.\u003c\/p\u003e\n\u003cp\u003eEverything you need to operate the ThermCal400 is included with the unit: one multiwell insert that accepts 1\/8\", 3\/16\", 1\/4\", 5\/16\" \u0026amp; 3\/8\" diameter probes, carrying strap, insert removal tool, mains cable and traceable cal certificate.\u003c\/p\u003e\n\u003cp\u003eApplications: temperature sensor calibration for RTD's\/PRT's, thermocouples, LIG thermometers, thermal switches, dial thermometers, hand held digital indicators, data logger and recorders and many other devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration Certificate\u003c\/strong\u003e\u003cbr\u003e\nThe ThermCal400 comes with an NIST traceable calibration certificate.  The temperature points on the certificate are given as °C but if °F is preferred please contact IOthrifty.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Blackbody Source Insert for Thermcal400 Dry Block Temperature Calibrator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/blackbodyinser1jpg_240x240.jpg?v=1666267492\" style=\"display: block; margin-left: auto; margin-right: auto; float: left;\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CL-AC-ATS3129 is a blackbody source insert for the ThermCal400 Dry Block Temperature Calibrator. In addition to checking standard surface contact temperature sensors like RTD’s, thermocouples, thermal switches, and indicators with the included insert, you can now purchase the Blackbody Source insert to check Infrared pyrometers and indicators. This option for the ThermCal400 makes it an economical choice for checking all of your temperature sensors.\u003cbr\u003e\u003cbr\u003eThere is no special calibration or change needed to use the Blackbody insert. Simply place it in the well using the insert extractor tool included with the unit. The accuracy using the Blackbody insert is  ±1.2°C (up to 200°C) and ±1.7°C (200 to 400°C) .  The Blackbody insert fits into the heater block just like the standard inserts using the insert extractor tool. The target source is 1.3” in diameter.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSee the \u003ca title=\"ThermCal130\" href=\"https:\/\/www.iothrifty.com\/products\/accurate-thermal-systems-thermcal130-temperature-calibrators\"\u003eThermCal130\u003c\/a\u003e\u003ca href=\"https:\/\/www.iothrifty.com\/products\/rht-climate-temperature-humidity-transmitter\" title=\"RHT-CLIMATE-WM\"\u003e\u003c\/a\u003e for a Calibrator for Low Temperature Applications\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/www.iothrifty.com\/products\/accurate-thermal-systems-thermcal130-temperature-calibrators\" title=\"ThermCal130\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/Thermcal130_view_with_included_accessories_240x240.jpg?v=1535204740\" alt=\"ThermCal130 Dry Block Calibrator\" style=\"margin-bottom: 16px; float: none; display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Requirements:\u003c\/strong\u003e 120 or 240 VAC mains supply 50\/60hz, 8 amp supply (120 volt version, 4 amp supply (240 volt version)\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"background-color: #c0ecfb;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the models below scroll to the top of the page and choose the desired model from the \"\u003cstrong\u003eModels\u003c\/strong\u003e\" drop down menu, then \u003cstrong\u003eADD TO CART\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3010\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eTHERMCAL400 DRY BLOCK CALIBRATOR - 120 VOLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3020\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eTHERMCAL400 DRY BLOCK CALIBRATOR - 240 VOLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 108px;\"\u003e\n\u003ctd style=\"height: 108px;\"\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 108px;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3043\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsert for five 1\/4\" probes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3044\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsert for two  1\/4\" probes and two 3\/8\" probes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3045\u003c\/td\u003e\n\u003ctd\u003eInsert for two 1\/4\" \u0026amp; two  1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3046\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsert for one 1\/4\" probe\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3047\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eBlank Insert \u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3048\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsert for one 9\/16\" probes\u0026amp; one 1\/4\" probes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3049\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsert for one  5\/8\" probes \u0026amp; one  1\/4\" probes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3050\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsert for one 11\/16\" probes \u0026amp; one 1\/4\" probes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3051\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsert for one  3\/4\" probes \u0026amp; one 1\/4\" probes\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3129\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eBlackbody Insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eCL-AC-ATS3052\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003eTHERMACAL400 CARRYING CASE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eDatasheets and Instruction Manuals\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca title=\"ThermCal400 Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/ThermCal400-brochure-V4.pdf?9775588703985514960\" target=\"_blank\"\u003eThermCal400 Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"ThermCal400 Instruction Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/ThermCal400_instruction_manual.pdf?9775588703985514960\" target=\"_blank\"\u003eThermCal400 Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE RANGE (22C ambient):\u003c\/strong\u003e 27C (80F) TO 400C (752F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCURACY:\u003c\/strong\u003e +\/-0.4C OR +\/-0.7F\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTABILITY:\u003c\/strong\u003e +\/-0.05C\/+\/-0.09F\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRADIANT UNIFORMITY (same sized wells):\u003c\/strong\u003e 0.025 AT 400C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHEAT UP TIME - ambient to max:\u003c\/strong\u003e 12 MINUTES\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOOL DOWN TIME -max to 100C:\u003c\/strong\u003e 20 MINUTES\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROBE WELL DEPTH \u0026amp; INSERT DIAMETER:\u003c\/strong\u003e 4.5\" DEPTH BY 1.5\" DIAMETER\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePOWER CONSUMPTION:\u003c\/strong\u003e 900 WATTS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERALL DIMENSIONS:\u003c\/strong\u003e 8\" H x 8\" W x 8\" L\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT WITH INSERT:\u003c\/strong\u003e 11 POUNDS\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWARRANTY:\u003c\/strong\u003e 2 YEARS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Accurate Thermal Systems","offers":[{"title":"120 Vac Power","offer_id":11648863961130,"sku":"CL-AC-ATS3010","price":2470.0,"currency_code":"USD","in_stock":true},{"title":"240 Vac Power","offer_id":11650698149930,"sku":"CL-AC-ATS3020","price":2470.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/thermcal400_with_included_accessories.jpg?v=1535204863"},{"product_id":"accurate-thermal-systems-thermcal130-temperature-calibrators","title":"ThermCal130 Temperature Calibrator for Heating and Cooling","description":"\u003cul\u003e\n\u003cli\u003eLaboratory Performance at an Economical Price\u003c\/li\u003e\n\u003cli\u003eLightweight and Portable for Use in the Field\u003c\/li\u003e\n\u003cli\u003eRemovable Probe Inserts for Flexibility \u0026amp; Many Probe Sizes\u003c\/li\u003e\n\u003cli\u003eRamp Rate Feature for Accurate Testing of Temperature Switches\u003c\/li\u003e\n\u003cli\u003eFast Heat Up \u0026amp; Stabilization\u003c\/li\u003e\n\u003cli\u003eOperating Range: -25°C(-4°F) to 130°C(266°F)\u003c\/li\u003e\n\u003cli\u003eCalibrated to C, contact IOThrifty.com for F calibration (no charge)\u003c\/li\u003e\n\u003cli\u003eCE, Designed \u0026amp; Mfg in the USA\u003c\/li\u003e\n\u003cli\u003eTraceable Cal Certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Thermcal130 by Accurate Thermal Systems is a a precision dry block calibrator suitable for high accuracy calibration of temperature probes including RTDs (PT100), thermocouples , thermistors and any other probe style temperature sensor.\u003c\/p\u003e\n\u003cp\u003eWith over 25 years of experience designing, manufacturing and supporting Dry Block Temperature Calibrators, Accurate Thermal Systems has developed two units that offer outstanding performance features and value that are unmatched in the market place. These units have a small footprint, a fast heat up and cool down time and weigh only 17 lbs (with an insert) for both field and laboratory use.\u003c\/p\u003e\n\u003cp\u003eUnlike many competing lower cost models that only offer a fixed block, these units accept inserts for probe size flexibility in addition to a fixed 1\/4\" reference hole.\u003c\/p\u003e\n\u003cp\u003eThe ThermCal130 controller offers a large, bright and easy to read display. Adjustable ramp rates for testing of thermal switches. The controller is switchable between F and C along with the ability to adjust unit calibration using the customer's own reference standard. Up to 8 set points can be saved for quick recall.\u003c\/p\u003e\n\u003cp\u003eIncluded in the unit is a fixed  1\/4\" reference hole, carrying strap, insert removal tool, main cable and traceable calibration certificate.\u003c\/p\u003e\n\u003cp\u003eFor continued years of reliable operation, in addition to the heat sink cooling fan, a small chassis cooling fan keeps the internal components and the controller cool at all operating temperatures.\u003c\/p\u003e\n\u003cp\u003eSystem requirements:120 or 240 VAC mains supply 50\/60mz, 2 amp supply (120 volt), 1 amp supply (240 volt)\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the models below scroll to the top of the page and choose the desired model from the \"\u003cstrong\u003ePower\u003c\/strong\u003e\" drop down menu, then \u003cstrong\u003eADD TO CART\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART  NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3080\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThermCal130 Dry Block Calibrator - 120 volt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3081\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eThermCal130 Dry Block Calibrator - 240 volt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3074\u003c\/td\u003e\n\u003ctd\u003eInsert 1\/8\" x 4\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3075\u003c\/td\u003e\n\u003ctd\u003eInsert 3\/16\" x 4\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3076\u003c\/td\u003e\n\u003ctd\u003eInsert 1\/4\" x 4\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3077\u003c\/td\u003e\n\u003ctd\u003eInsert 5\/16\" x 4\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3078\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eInsert 3\/8\" x 4\" deep\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3052\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCarrying case\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eInserts may be ordered on the\u003ca href=\"https:\/\/www.iothrifty.com\/products\/inserts-for-thermcal130-temperature-calibrator\" title=\"https:\/\/www.iothrifty.com\/products\/inserts-for-thermcal130-temperature-calibrator\" target=\"_blank\"\u003e Inserts for Thermcal130 Temperature Calibrator webpage\u003c\/a\u003e.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"472\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 467.917px;\"\u003e\u003cstrong\u003e Datasheets and Operating Manuals\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 74.4167px;\"\u003e\n\u003ctd style=\"height: 74.4167px; width: 467.917px;\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/ThermCal130-brochure-rev7.pdf?18134148953460518285\" title=\"ThermCal130 Datasheet\" target=\"_blank\"\u003eThermCal130 Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/ThermCal130_instruction_manual.pdf?18134148953460518285\" title=\"ThermCal130 Operating Instructions\" target=\"_blank\"\u003eThermCal130 Operating Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE RANGE:\u003c\/strong\u003e -25\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eC (-4\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eF) to 130\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eC (266\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eF)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCURACY:\u003c\/strong\u003e +\/-0.4\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eC\/+\/-0.7\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eF\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTABILITY:\u003c\/strong\u003e \u0026gt; +\/-0.05\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eC\/+\/-0.09\u003cspan id=\"degree-symbol\" class=\"font3\" data-mce-fragment=\"1\"\u003e°\u003c\/span\u003eF\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHEAT UP TIME -20 to 130C:\u003c\/strong\u003e 8 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHEAT UP TIME 20 to 100C:\u003c\/strong\u003e 3 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOOL DOWN TIME 20 to -20C:\u003c\/strong\u003e 9 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOOL DOWN TIME 130 to 20C:\u003c\/strong\u003e 4 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROBE WELL DEPTH \u0026amp; INSERT DIAMETER:\u003c\/strong\u003e 4\" depth by 1\/2\" diameter\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePOWER CONSUMPTION:\u003c\/strong\u003e 150 watts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOVERALL DIMENSIONS:\u003c\/strong\u003e 10.2\" H x 9\" W x 8\" L\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT WITH INSERT:\u003c\/strong\u003e 17 lbs\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWARRANTY:\u003c\/strong\u003e 2 years\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Accurate Thermal Systems","offers":[{"title":"120 Vac","offer_id":11655350026282,"sku":"CL-AC-ATS3080","price":2985.0,"currency_code":"USD","in_stock":true},{"title":"240 Vac","offer_id":11659417845802,"sku":"CL-AC-ATS3081","price":2985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/Thermcal130_view_with_included_accessories.jpg?v=1535204740"},{"product_id":"ftbsl6-fluidized-temperature-baths","title":"Fluidized Temperature Baths Model FTBSL6","description":"\u003cul\u003e\n\u003cli\u003eFully Automatic Fluidizing Air Control\u003c\/li\u003e\n\u003cli\u003eCover and Lid Design that Minimizes Media Loss\u003c\/li\u003e\n\u003cli\u003eIndependent Over-Temperature Limit Protection\u003c\/li\u003e\n\u003cli\u003eFast Heat Up, Excellent Stability, Uniformity \u0026amp; Accuracy\u003c\/li\u003e\n\u003cli\u003e1900 Watt Heat Capacity\u003c\/li\u003e\n\u003cli\u003eCompact Size for Placement on Standard Lab Benches\u003c\/li\u003e\n\u003cli\u003ePortable, only 45 lbs with Aluminum Oxide\u003c\/li\u003e\n\u003cli\u003eRS485 Interface for PC Connection \u0026amp; Downloadable Windows Software\u003c\/li\u003e\n\u003cli\u003eCE, Designed \u0026amp; Mfg in USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIOThrifty has a range of products that offer outstanding performance, safety, features and value that are unmatched in the marketplace. Unlike competing Fluidized baths, these systems have a smaller footprint, include advanced features and cost thousands of dollars less. In addition, they are much safer than salt baths with thermal response that is 2 to 3 times faster than ovens.\u003c\/p\u003e\n\u003cp\u003eFluidized Temperature Baths have been the heat source of choice for over 20 years by many Fortune 500 plastic, medical device manufacturers as well as companies who require fast heat up of their immersed devices, sensors and materials with minimal quenching.\u003c\/p\u003e\n\u003cp\u003eUnique bath cover and lid design minimizes media loss. Media loss is either blocked by the lid or collected on the cover flange which then drops back into the system. The lid with handle is lowered into the fluidized bath for cleaning parts, heat treating or calibrating temperature sensors.\u003c\/p\u003e\n\u003cp\u003eAn eyelet is added to the lid for suspending an optional basket (part # CL-AC-ATS1080) for parts cleaning or device heat treatment. The optional probe support (part # CL-AC-ATS3082) will suspend temperature sensors and thermometers into the fluidized bath for calibration. The probe holder immersion depth can be adjusted for  added flexibility. Drill holes into the lid for the diameters you require. The lid is easily modified for immersing apparatus, assemblies and small reactors for heating.\u003c\/p\u003e\n\u003cp\u003eApplications: thermal cleaning of small extrusion tooling, polymer rheometer and melt flow indexers parts, nitinol stent shape setting, temperature sensor and system calibration, reactor heating, and general heat treatment of devices and materials.\u003c\/p\u003e\n\u003cp\u003eSystem Requirement: 120 VAC mains, 50\/60 hz-20 amp supply or 240 VAC mains, 50\/60 hz-10 amp supply. A clean air supply at a fixed 30 PSI, max flow of 1.8CFM.\u003c\/p\u003e\n\u003cp\u003eUnits come with: 20 lbs of media, bath cover and lid.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the models below scroll to the top of the page and choose the desired model from the \"\u003cstrong\u003eInput Power\u003c\/strong\u003e\" drop down menu, then \u003cstrong\u003eADD TO CART\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART NUMBERS\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS2016\u003c\/td\u003e\n\u003ctd\u003eFLUIDIZED SAND BATH, 120 VOLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS2018\u003c\/td\u003e\n\u003ctd\u003eFLUIDIZED SAND BATH, 240 VOLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACCESSORIES\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS1078\u003c\/td\u003e\n\u003ctd\u003eSPARE LID w\/HANDLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS1080\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBASKET, 3.5\" x 5\" DEPTH\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS1076\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSPARE ALUMINUM OXIDE, 20 LBS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-AC-ATS3082\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePROBE SUPPORT for TEMPERATURE SENSORS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e Videos\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.iothrifty.com\/blogs\/videos\/iothrifty-ftbsl6-fluidized-bath-for-thermal-cleaning-and-temperature-calibration\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/Fluidized-Temp-Bath_480x480.png?v=1701705319\" width=\"399\" height=\"221\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/www.iothrifty.com\/blogs\/videos\/iothrifty-ftbsl6-fluidized-bath-for-thermal-cleaning-and-temperature-calibration\" title=\"IOThrifty FTBSL6 Fluidized Bath for Thermal Cleaning and Temperature Calibration\"\u003eIOThrifty FTBSL6 Fluidized Bath for Thermal Cleaning and Temperature Calibration\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cstrong\u003e Datasheets, Operating Manuals and Downloads\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 332.417px;\"\u003e\n\u003ctd style=\"height: 332.417px;\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/FTBSL6-Fluidized-Bath-brochure-rev5.pdf?3146331669542319229\" title=\"FTBSL6 Fluidized Bath Datasheet\" target=\"_blank\"\u003eFTBSL6 Fluidized Bath Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/FTBSL6_instruction_manual.pdf?3146331669542319229\" title=\"FTBSL6 Instruction Manual\" target=\"_blank\"\u003eFTBSL6 Instruction Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/accuthermal.com\/fluidized-temperature-baths\/\" title=\"FTBSL6 downloads\" target=\"_blank\"\u003eVisit the FTBSL6 page\u003c\/a\u003e on the Accurate Thermal Systems website to download:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSDS for Brown Aluminum oxide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eSDS for White Activated Alumina\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAccuTherm FTB Software V814\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eFume Ventilation Diagrams for Fluidized Baths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eCE Declaration of Conformance Fluidized Baths\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE RANGE:\u003c\/strong\u003e 50 TO 605C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWORKING VOLUME:\u003c\/strong\u003e 5.3 dia x 6\" depth (134mm X 152mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTYPICAL STABILITY THRU OPERATING RANGE:\u003c\/strong\u003e +\/-0.3C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDEAD BED STABILITY (5 minute period):\u003c\/strong\u003e +\/-0.04C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCALIBRATED ACCURACY:\u003c\/strong\u003e +\/-2.0C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHEAT UP TIME TO 600C FROM AMBIENT:\u003c\/strong\u003e 70 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOOL DOWN TIME, 600C TO 200C:\u003c\/strong\u003e 130 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHEAT POWER, 1 PHASE, 50\/60 HZ:\u003c\/strong\u003e 1920 watts\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAIR PRESSURE \u0026amp; MAX FLOW REQUIRED:\u003c\/strong\u003e 30 PSI, 1.8 CFM (2.1 bar, 50 lpm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 15\" H x 17\" W x 13\" D (381mm x 432mm x 330mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT w\/ALUMINUM  OXIDE:\u003c\/strong\u003e 45 lbs (unit only 32 lbs, 14.5 kgs)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWARRANTY:\u003c\/strong\u003e 1 year\u003c\/p\u003e\n\u003cp\u003e\u003ci\u003eThis is an oversized product so the website shipping rates for expedited shipping methods may not apply.  IOThrifty will provide a quote for expedited shipping rates after the purchase.  Please contact us if you would like a quote before purchasing.\u003c\/i\u003e\u003c\/p\u003e","brand":"Accurate Thermal Systems","offers":[{"title":"120Vac","offer_id":11678583193642,"sku":"CL-AC-ATS2016","price":7495.0,"currency_code":"USD","in_stock":true},{"title":"240Vac","offer_id":11680402014250,"sku":"CL-AC-ATS2018","price":7495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/FTBSL6-1.jpg?v=1781715493"},{"product_id":"thermocouple-millivolt-calibrator-source-322","title":"Thermocouple Calibrator\/Source  with Display, Auto Step, 4 T\/C Types Plus mV, Model 322 by PIE","description":"\u003cul\u003e\n\u003cli\u003eEasy to Use\u003c\/li\u003e\n\u003cli\u003eSource and Read Four T\/C Types Plus mV (J\/K\/T\/E, -13.000 to 8.000 mV)\u003c\/li\u003e\n\u003cli\u003eResolution to 0.1 F\/C, Accurate to 0.2C (Cold Junction Sensor Accurate to 0,05C)\u003c\/li\u003e\n\u003cli\u003e Faster Calibrations (Instantly Select 3 Outputs with EZ-CHECK Switch; Easily Find Trip Points w\/2 Speed EZ DIAL Knob \u0026amp; Automatic Stepping)\u003c\/li\u003e\n\u003cli\u003eEasily Change T\/C Types \u0026amp; Scale (Double Click to Select T\/C Types \u0026amp; F\/C)\u003c\/li\u003e\n\u003cli\u003eEasy-to-Read Display (Turn On the Backlight to Read in Dark Areas of the Plant)\u003c\/li\u003e\n\u003cli\u003eUse in the Plant, Field or Shop (Includes Rubber Boot, mV Test Leads, Low Profile Switches Resist Accidental Damage, Brass Screws for T\/C Wire Plus Mini T\/C Socket)\u003c\/li\u003e\n\u003cli\u003eComes with Protective Rubber Boot, Carrying Case, Certificate of Calibration, Alligator to Banana Test Leads, 4-AA Batteries\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #274e13;\"\u003e\u003cstrong\u003eIn Stock for FAST and FREE Delivery\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePIE'S 322-1 is designed for easy use. With the 322-1 you can check and calibrate all your thermocouple instruments and measure thermocouple sensors. You can take it to the shop, plant or field. Carry it without worry as it comes protected with a rubber boot and rugged low profile switches. Easy to operate even in dark areas of the plant with the  backlit display.\u003c\/p\u003e\n\u003cp\u003eCalibrate directly in temperature, C\/F. You now can stop carrying around a millivolt source and thermocouple tables. The 322-1 works with the 4 most common thermocouples (J\/K\/T\/E). Easily set any value quickly to within 0.1C with the adjustable digital potentiometer \"DIAL\" plus store any 3 temperatures  for instant recall with the EZ-CHECK switch. Or calibrate from -13.000 to + 80.000mV.\u003c\/p\u003e\n\u003cp\u003eFast calibration with automatic output stepping. You can choose between 2, 3, 5, 11 steps and ramp to automatically increment the outputs in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, 60 seconds.\u003c\/p\u003e\n\u003cp\u003eComparable with all process instruments. No competitors calibrator is compatible with as many process instruments as PIE'S 322-1. Connect directly to the thermocouple inputs of transmitters, PLCs, DCS \u0026amp; multichannel recorders to verify their outputs or displays.\u003c\/p\u003e\n\u003cp\u003eMeasure thermocouple sensors. Trouble shoot sensor connections and find broken wires or corroded connections. Connect your thermocouple and the 322-1 measures the probe in degrees C\/F.\u003c\/p\u003e\n\u003cp\u003eCalibration lab accurate and stable. The internal cold junctions thermistor is accurate to +\/-0.1C and is traceable to NIST. The sensor is thermally bonded to an isothermal mass which includes brass blocks with screw terminals for connection of bare thermocouple wires along with a  mini thermocouple connection for fast connections. The circuitry uses an extremely stable voltage reference and low drift components which makes the 322-1 more accurate than most other handheld and benchtop thermocouple calibrators.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on \u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003cstrong\u003e\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e PART NUMBER\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-322-1\u003c\/td\u003e\n\u003ctd\u003eT\/C CALIBRATOR J\/T\/E\/K, mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCURACY:\u003c\/strong\u003e +\/-(0.008% of Reading + 0.006 mV)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOLD JUNCTION COMPENSATION:\u003c\/strong\u003e +\/-0.1C Themistor traceable to NIST for 11 years\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMILLIVOLT RANGE:\u003c\/strong\u003e -13.000 to 80.000mV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMPERATURE RANGE:\u003c\/strong\u003e -25 to 60C (-10 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE EFFECT:\u003c\/strong\u003e \u0026lt; +\/-50 ppm\/C; Cold Junction Sensor \u0026lt; +\/-25 ppm\/C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10%\u0026lt;RH \u0026lt;90% (0 to 35C) Non-Condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 5.63 x 3.00 x 1.60 inches\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 12.1 oz, including boot and batteries (4-AA)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY LIFE:\u003c\/strong\u003e 50 hrs\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLOW BATTERY WARNING:\u003c\/strong\u003e 1 hr of life left\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTIONS:\u003c\/strong\u003e Over-voltage protection to 60 V dc (rated for 30 seconds)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e High contrast graphic LCD. LED backlight for use in low lit areas\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInput impedance: \u0026gt; 10 Megohms\u003c\/p\u003e\n\u003cp\u003eOpen t\/c:  threshold 10,000 ohms nominal; pulse \u0026lt; 10 microamp pluse for 400 milliseconds\u003c\/p\u003e\n\u003cp\u003eNormal Mode Rejection: 50\/60 Hz, 50 dB\u003c\/p\u003e\n\u003cp\u003eCommon Mode Rejection: 50\/60 Hz, 120 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOutput Impedance: \u0026lt; 0.3 ohms\u003c\/p\u003e\n\u003cp\u003eSource current: \u0026gt; 20 mA (drives 80 mV into 10 ohms)\u003c\/p\u003e\n\u003cp\u003eNoise: \u0026lt; 4 microvolts p-p for frequencies of 10 Hz or below\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12543441600554,"sku":"CL-PI-322-1","price":1585.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/CL-PI-322-1.png?v=1535205166"},{"product_id":"pie-single-type-t-c-calibrator-source-only-plus-mv","title":"520B Thermocouple Calibrator\/Source - One T\/C Input Type Plus mV","description":"\u003cul\u003e\n\u003cli\u003eEasy To Use; Take It Into the Shop, Plant or Field\u003c\/li\u003e\n\u003cli\u003eAccuracy +\/-(0.015% of mV Setting + 0.009mV)\u003c\/li\u003e\n\u003cli\u003eCalibrate Directly In C\/F for Your Type T\/C\u003c\/li\u003e\n\u003cli\u003eAdjustable Temperature Output in Selectable 0.1C or 0.1F Steps\u003c\/li\u003e\n\u003cli\u003eSource One of 14 T\/C Types: J\/K\/E\/T\/R\/S\/B\/N\/G\/C\/D\/L\/U\/P\u003c\/li\u003e\n\u003cli\u003eTypical Accuracy of +\/-0.35C (0.5) for Type K\u003c\/li\u003e\n\u003cli\u003eEZ-Dial Knob Easily Adjusts Output By C\/F w\/0.1C Resolution\u003c\/li\u003e\n\u003cli\u003e3 Position EZ-Check Switch for 0% and 100% Span Adjustments\u003c\/li\u003e\n\u003cli\u003eCompatible with All Process Instruments\u003c\/li\u003e\n\u003cli\u003eSuperior Battery Life (45 hrs under typical usage)\u003c\/li\u003e\n\u003cli\u003eEasy Access to battery Compartment\u003c\/li\u003e\n\u003cli\u003eComes with Alligator to Banana Test Leads, NIST Traceable Cal Cert, 4-AA Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 520B single type T\/C simulator simulates a dedicated standard thermocouple curve over the entire industrial temperature range. The 520B provides precise temperature for inputs to all types of instruments such as transmitters, recorders, controllers, alarms, data acquisition, and computer systems. 520B is cold-junction compensated for changes in ambient temperature. And offers the highest performance and functions in its class by exceeding the accuracy and functions of many higher priced thermocouple calibrators\u003c\/p\u003e\n\u003cp\u003eThe low price offered by IOThrifty of 520B is \"easy as PIE\" to use thermocouple source for checkout and calibration of all thermocouple instruments in the field, shop or control room.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the models below scroll to the top of the page and choose the desired model from the \"\u003cstrong\u003eModels\u003c\/strong\u003e\" drop down menu, then \u003cstrong\u003eADD TO CART\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-J\u003c\/td\u003e\n\u003ctd\u003eTYPE J T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-K\u003c\/td\u003e\n\u003ctd\u003eTYPE K T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-T\u003c\/td\u003e\n\u003ctd\u003eTYPE T T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-E\u003c\/td\u003e\n\u003ctd\u003eTYPE E T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-R\u003c\/td\u003e\n\u003ctd\u003eTYPE R T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-S\u003c\/td\u003e\n\u003ctd\u003eTYPE S T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-B\u003c\/td\u003e\n\u003ctd\u003eTYPE B T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-G\u003c\/td\u003e\n\u003ctd\u003eTYPE G T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-C\u003c\/td\u003e\n\u003ctd\u003eTYPE C T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-D\u003c\/td\u003e\n\u003ctd\u003eTYPE D T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-N\u003c\/td\u003e\n\u003ctd\u003eTYPE N T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-L\u003c\/td\u003e\n\u003ctd\u003eTYPE L T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-U\u003c\/td\u003e\n\u003ctd\u003eTYPE U T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-520B-P\u003c\/td\u003e\n\u003ctd\u003eTYPE P T\/C CALIBRATOR, SOURCE ONLY PLUS mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCURACY:\u003c\/strong\u003e +\/-(0.015% of reading + 0.009 mV)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOLD JUNCTION COMPENSATION:\u003c\/strong\u003e +\/- 0.45F (+\/-0.25%C)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMILLIVOLT  RANGE:\u003c\/strong\u003e -13.000 to 80.000mV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMP RANGE:\u003c\/strong\u003e -25 to 60C (-10 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH \u0026lt;90% (0 to 35C), non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 4.96 x 2.73 x 1.79 in (126 x 69 x 45 mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 8.4 oz (0.24 kg) including batteries\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY LIFE:\u003c\/strong\u003e 50 hrs; low battery warning with 1 hr left\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e Over-voltage protection to 60 V dc (rated for 30 seconds)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e High contrast graphic LCD; LED backlight for use in low lit areas\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOutput impedance \u0026lt; 0.3 ohms\u003c\/p\u003e\n\u003cp\u003eSource current \u0026gt; 20mA (drives 80 mV into 10 ohms)\u003c\/p\u003e\n\u003cp\u003eNoise \u0026lt; 4 microvolts p-p for frequencies of 10 Hz or below\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"J T\/C, Millivolt Input","offer_id":12551670104106,"sku":"CL-PI-520B-J","price":908.0,"currency_code":"USD","in_stock":true},{"title":"K T\/C, Millivolt Input","offer_id":12552262746154,"sku":"CL-PI-520B-K","price":908.0,"currency_code":"USD","in_stock":true},{"title":"T T\/C, Millivolt Input","offer_id":12552262778922,"sku":"CL-PI-520B-T","price":908.0,"currency_code":"USD","in_stock":true},{"title":"E T\/C, Millivolt Input","offer_id":12552262811690,"sku":"CL-PI-520B-E","price":908.0,"currency_code":"USD","in_stock":true},{"title":"R T\/C, Millivolt Input","offer_id":12552262844458,"sku":"CL-PI-520B-R","price":908.0,"currency_code":"USD","in_stock":true},{"title":"G T\/C, Millivolt Input","offer_id":12552262877226,"sku":"CL-PI-520B-G","price":908.0,"currency_code":"USD","in_stock":true},{"title":"S T\/C, Millivolt Input","offer_id":12552262909994,"sku":"CL-PI-520B-S","price":908.0,"currency_code":"USD","in_stock":true},{"title":"B T\/C, Millivolt Input","offer_id":12552262942762,"sku":"CL-PI-520B-B","price":908.0,"currency_code":"USD","in_stock":true},{"title":"C T\/C, Millivolt Input","offer_id":12552262975530,"sku":"CL-PI-520B-C","price":908.0,"currency_code":"USD","in_stock":true},{"title":"D T\/C, Millivolt Input","offer_id":12552263008298,"sku":"CL-PI-520B-D","price":908.0,"currency_code":"USD","in_stock":true},{"title":"N T\/C, Millivolt Input","offer_id":12552263041066,"sku":"CL-PI-520B-N","price":908.0,"currency_code":"USD","in_stock":true},{"title":"L T\/C, Millivolt Input","offer_id":12552263073834,"sku":"CL-PI-520B-L","price":908.0,"currency_code":"USD","in_stock":true},{"title":"U T\/C, Millivolt Input","offer_id":12552263106602,"sku":"CL-PI-520B-U","price":908.0,"currency_code":"USD","in_stock":true},{"title":"P T\/C, Millivolt Input","offer_id":12552263139370,"sku":"CL-PI-520B-P","price":908.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/CL-PI-520B.jpg?v=1535205145"},{"product_id":"pie-rtd-calibrator-source-only-plus-ohms","title":"510B RTD (PT100) Simulator\/Source Plus  Ohms","description":"\u003cul\u003e\n\u003cli\u003eEasy to Use; Take It Into the Shop, Plant or Field\u003c\/li\u003e\n\u003cli\u003eSimulates 1 Type, Pt100, 0.00385\u003c\/li\u003e\n\u003cli\u003eCalibrate Directly in C\/F\u003c\/li\u003e\n\u003cli\u003eCompatible With All Process Instruments\u003c\/li\u003e\n\u003cli\u003eNist Certificate Included\u003c\/li\u003e\n\u003cli\u003eAccurate to +\/-0.25C (+\/-0.5F) for Pt 100 Ohms RTD's w\/0.1C Resolution\u003c\/li\u003e\n\u003cli\u003eGuaranteed Compatible w\/Devices Using Pulsed Excitation Currents Including PLCs, DCS, Multi Channel Recorders\u003c\/li\u003e\n\u003cli\u003eEZ-DIAL Knob With 2 Dialing Speeds Makes Adjusting Output Easy\u003c\/li\u003e\n\u003cli\u003eEZ-Check Switch Stores Settings for 0% \u0026amp; 100% Span Adjustments\u003c\/li\u003e\n\u003cli\u003eBattery Life 45 Hrs Under Typical Continuous Usage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 510B-PT-100-1 simulates RTD resistances into all types of process instruments including transmitters, recorders, controllers, alarms, data aquisition, and computer systems. No longer will you need to lug a decade box around or make errors reading RTD tables incorrectly. The 510B-PT-100-1 is a superior replacement for decade boxes by allowing you to dial directly in temperature. It also has better accuracy than many higher priced calibrators.\u003c\/p\u003e\n\u003cp\u003eWith the 510B-PT-100-1 you can continuously select output temperatures. And you can instantly select 3 outputs ranges by flipping the EZ-Check switch to calibrate zero, span and mid-point. Built-in LCD display with backlight helps for easy viewing in dark locations.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on \u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003cstrong\u003e\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-510B-PT-100-1\u003c\/td\u003e\n\u003ctd\u003eRTD Simulator, 1 Type (Pt100, 0.00385)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e Comes with NIST Cert, 4-AA alkaline batteries,  2 red \u0026amp; 2 black leads w\/retracable shield banana plugs \u0026amp; spade lugs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e (unless otherwise indicated all specs are rated from a nominal 23C, 70% RH for 1 year from calibration)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCURACY:\u003c\/strong\u003e +\/-(0.015% of setting in ohms + 0.05 ohms)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE DRIFT:\u003c\/strong\u003e +\/- 0.05 ohms\/C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMP RANGE:\u003c\/strong\u003e -25 to 60C (-10 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH \u0026lt;90% (0 to 35C) non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 4.96 x 2.73 x 1.79 in (126 x 69 x 45 mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 8.4 oz (0.24 kg (including 4 AA batteries)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY LIFE:\u003c\/strong\u003e 45 hrs with low battery warning of 1 hr left\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e Over-voltage protection to 60 V dc (rated for 30 seconds)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e High contrast LCD with LED backlight for use in dim lit areas\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSIMULATE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy from 1 to 10.2 mA external excitation current: +\/-(0.015% of setting + 0.005 ohms)\u003c\/p\u003e\n\u003cp\u003eAccuracy below 1 mA of external excitation: +\/-(0.015% of setting +0.01mV\/mA excitation current + 0.05 ohms)\u003c\/p\u003e\n\u003cp\u003eResistance ranges, 0.00 to 410.00, 410.1 to 4001.0 ohms\u003c\/p\u003e\n\u003cp\u003eAllowable excitation current range, \u0026lt;410 ohms: 10.2 mA max; steady or pulsed\/intermittent\u003c\/p\u003e\n\u003cp\u003ePulsed excitation current compatibility DC to 0.01 seconds pulse width\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12560379805738,"sku":"CL-PI-510B-PT-100-1","price":915.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIECAL_510B_without_optional_boot.jpg?v=1535205292"},{"product_id":"pie-311-rtd-process-calibrator-w-patented-rtd-wire-detection","title":"RTD Process Calibrator w\/Patented RTD Wire Detection, Model 311 by PIE","description":"\u003cul\u003e\n\u003cli\u003eCalibrate with ease with resolution to 0.1 F\/C \u0026amp; accuracy to 0.2C\u003c\/li\u003e\n\u003cli\u003eSource and read multiple RTD curves plus ohms. Platinum 100 ohms: 1.3850, 1.3902, 1.3916,13926. Platinum 1000 ohms: 1.3850, 1.3750. Copper 10 \u0026amp; 50 ohms. Nickel 120 ohms, 0.00 to 4001.0 ohms\u003c\/li\u003e\n\u003cli\u003eComes with NIST certificate, rubber boot, carrying case, 2 red \u0026amp; 2 black leads w\/banana plugs \u0026amp; spade lugs\u003c\/li\u003e\n\u003cli\u003eAutomatically detect 2, 3, \u0026amp; 4 wire connections\u003c\/li\u003e\n\u003cli\u003eGuaranteed compatible with all instrumentation\u003c\/li\u003e\n\u003cli\u003eInstantly select 3 outputs with the EZ-CHECK switch\u003c\/li\u003e\n\u003cli\u003eEasily find trip points w\/2 speed EZ-DIAL knob \u0026amp; auto stepping\u003c\/li\u003e\n\u003cli\u003eEasily change RTD types and F\/C scale\u003c\/li\u003e\n\u003cli\u003eVerify RTD temperature \u0026amp; output\u003c\/li\u003e\n\u003cli\u003eTurn on the backlight to easily read in dark areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe PIE 311 is designed to be easily used. You can check and calibrate all your RTD instruments and measure RTD sensors. You have automatic indication of connections on the display for simple hook-ups. And now you can stop carrying around a decade box and RTD resistance tables. The PIE 311 works with the RTDs you use including Platinum 100 (alpha = 3850, 3902, 3926) and 1000 (alpha = 3850, 3750) Ohm, Copper 10 \u0026amp; 50 Ohm and Nickel 120 Ohm. Easily set any value quickly to within 0.1C with the adjustable digital potentiometer \"DIAL\" plus store any 3 temperatures for instant recall with the EZ-CHECK switch.\u003c\/p\u003e\n\u003cp\u003eUser can quickly choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. You can also select the step time to match your system from 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, 60 seconds.\u003c\/p\u003e\n\u003cp\u003eWith patented technology, the PIE 311 trouble shoots sensor connections to find  broken wires. You can connect your 2, 3, or 4 wire RTDs and the PIE 311 will automatically detect connections and measure the RTD in degrees C\/F. The secondary display will show the resistance value corresponding to the RTD temperature.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on \u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003cstrong\u003e\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e PART NUMBER\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-311\u003c\/td\u003e\n\u003ctd\u003eRTD PROCESS CALIBRATOR w\/RTD WIRE DETECTION\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDatasheets and User Manuals\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-311-9001-Rev-E-Automated-Universal-RTD-Calibrator-Datasheet.pdf?17822458146514850831\" title=\"PIECAL-311 Universal RTD Calibrator Datasheet\"\u003ePIECAL 311 Universal RTD Calibrator Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-311-9001-Rev-E-Automated-Universal-RTD-Calibrator-Datasheet.pdf?17822458146514850831\" title=\"PIECAL-311 Universal RTD Calibrator Datasheet\"\u003ePIECAL-311 Universal-RTD-Calibrator Operating Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eACCURACY:\u003c\/strong\u003e +\/-(0.015% of reading + 0.05 Ohms)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE DRIFT:\u003c\/strong\u003e +\/- 0.01% of span outside of 23C +\/-10C (73C +\/-18F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMPERATURE RANGE:\u003c\/strong\u003e -25 to 60C (-10 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH \u0026lt;90% (0 to 35C) non-condensing; 10% \u0026lt;RH \u0026lt;70% (35 to 60C) non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 5.63 x 3.00 x 1.60 in (143 x 76 x 41 mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 12.1 oz (0.34 kg) including boot \u0026amp; 4-AA batteries\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY LIFE:\u003c\/strong\u003e 50 hrs w\/ low battery indication (1 hr left)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e over-voltage protection to 60 V dc (rated for 30 seconds)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e high contrast graphic LCD. LED backlight for use in low lit areas\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExcitation Current: 0.9 mA to 401 Ohm, 0.4 mA to 4010 Ohms (nominal)\u003c\/p\u003e\n\u003cp\u003eNormal Mode Rejection: 50\/60 Hz, 50 dB\u003c\/p\u003e\n\u003cp\u003eCommon Mode Rejection: 50\/60 Hz, 120 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 \u0026amp; 4 Wire Accuracy from 1 to 10.2 mA External Excitation Current: +\/-(0.015% of reading + 0.05 Ohms)\u003c\/p\u003e\n\u003cp\u003eBelow 1 mA of External Excitation Current: +\/-(0.015% of Rdg + 0.025 mV\/mA Excitation Current +0.05Ohms)\u003c\/p\u003e\n\u003cp\u003e2 Wire Accuracy: add 0.1 Ohms to 3 \u0026amp; 4 wire accuracy\u003c\/p\u003e\n\u003cp\u003eResistance Ranges, 0.00 to 401.00, 0.0 to 4010.0 Ohms\u003c\/p\u003e\n\u003cp\u003eAllowable Excitation Current Range, 400 Ohms range, 10.2 mA max, steady or pulse\/intermittent; 4000 Ohms range, 1 mA max, steady or pulse\/intermittent\u003c\/p\u003e\n\u003cp\u003ePulsed Excitation Current Compatibility, DC to 0.01 second pulse width\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12570014384170,"sku":"CL-PI-311","price":1995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIE-311-in-Red-Boot-Rev-A-Nov-2015.jpg?v=1535204976"},{"product_id":"pie-820-6-function-process-calibrator","title":"820\/ 6 Function Process Calibrator","description":"\u003cul\u003e\n\u003cli\u003eCarry 6 Single Function Calibrators In the Palm of Your Hand\u003c\/li\u003e\n\u003cli\u003eIntuitive EZ-DIAL Double Click Menu Is Easy to Setup\u003c\/li\u003e\n\u003cli\u003eUse  as a Milliamp \u0026amp; Voltage Meter\u003c\/li\u003e\n\u003cli\u003eCalibrate in C\/F: T\/C J\/K\/T\/E\/R\/S\/B\/N\/G\/C\/D\/L\/U\/P; Pt 100 Ohm (3850, 3902, 3916, 3926) \u0026amp; 1000 Ohm (3850) Copper 10 \u0026amp; 50 Ohm; Nickel 110 \u0026amp; 120 Ohm\u003c\/li\u003e\n\u003cli\u003eSource \u0026amp; Read Frequency to 2000 CPM, 999.99 Hz, 9999.9 Hz to 20.000 kHz\u003c\/li\u003e\n\u003cli\u003eTroubleshoot loop \u0026amp; Wiring Problems\u003c\/li\u003e\n\u003cli\u003eEasily Set Any 3 Outputs Plus Automatic Stepping \u0026amp; Ramping\u003c\/li\u003e\n\u003cli\u003eMeasure Temperature Sensors, Frequency Pickups, Loop Currents \u0026amp; Voltage Levels\u003c\/li\u003e\n\u003cli\u003eComes With NIST Certificate, Rubber Boot, Carrying Case, 1 Red, 1 Black Lead w\/ Banana to Alligator Clip, 2 Red, 2 Black Leads w\/Banana to Spade Lugs, Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThermocouple Calibrator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe easy to use 820 allows you to calibrate thermocouples directly in C\/F. Quickly set any value to within 0.1C with the adjustable digital potentiometer EZ-DIAL plus recall any 3 temperatures for instant recall with the EZ-CHECK switch. Measure thermocouple sensors; trouble shoot sensor connections to find broken wires or corroded connections. Connect your thermocouple with a mini thermocouple connector and the PIE 820 measures the probes in C\/F.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRTD, Resistance Calibrator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith the 820 you can check and calibrate all your RTD instruments and measure RTD sensors and show automatic indication of connections on the display for simple hook-ups. The PIE 820 works with the RTDs you use including Platinum 100 (alpha = 3850, 3902, 3916, 3926) \u0026amp; 1000 (alpha =  3850) Ohm, Copper 10 \u0026amp; 50 Ohm, Nickel 100 and 120 Ohm. Easily set any value quickly to within 0.1C with the adjustable digital potentiometer EZ-DIAL plus store any 3 temperatures for instant recall with the EZ-CHECK switch. Or use like a decade box from 0.0 to 401.0 and from 0 to 4010 Ohms. The 820 is compatible with all process instruments. Connect directly to the RTD inputs of smart transmitters, PLCs, DCS and multichannel recorders and verify their outputs or displays. The 820 works with older instruments with fixed excitation currents and newer multichannel instruments that switch the excitation current between input channels. And with the PIE 820 you can measure RTD sensors and trouble shoot sensor connections to find broken wires. Connect 2, 3 or 4 wires RTDs and the 820 measures the RTD in C\/F.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMilliamp Calibrator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck, calibrate and measure all your current signal instruments in a 4 to 20 milliamp DC loop. Access any point in the loop. Source \u0026amp; Read 0.00 to 24.00 mA. Simulate a 2 wire transmitters or use the 820 to simultaneously power your 2 wire transmitter and measure its output. Source milliamps; calibrate recorders, digital indicators, stroke valves or any instrument that get their input from a 4 to 20 mA loop. Easily set any value quickly to within 0.01 mA with the adjustable digital potentiometer EZ_DIAL or use preset 4.00 mA (0.0%) and 20.00 mA (100.0%) EZ-CHECK settings. The 820 can read loop current, calibrate using loop power and power and measure 2 wire transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Calibrator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can check, calibrate and measure all your voltage, millivolt and pH signal instruments. Source 0 to 10.25 V dc and -10.00 to 80.00 mV. Read DC volts; You can measure from 10.25V, -10.00 to 80.00mV and 0.0 to 60.0 VDC. Use the  PIE 820 to check loop power supplies, I\/V converters, 1 to 5 volt signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Calibrator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCalibrate flow meters and frequency instruments; generate zero crossing square wave to check, calibrate and measure all the frequency signal instruments in your facility. Source and read frequencies from 1 to 2000 CPM, 0.01 to 999.00Hz, 0.1 to 9999.9 Hz and 0.001 to 20.000kHz. The PIE 820 has a green LED that flashes in sync with the output frequency. Select a frequency and hold the calibrator up to the optical sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContinuity Checker\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTroubleshoot wiring and connection problems; use the built-in continuity checker to look at wiring and connections during installation or to locate shorts. 820 will beep from 0.100 Ohms.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on \u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-820\u003c\/td\u003e\n\u003ctd\u003ePIE 6 Function Process Calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e Datasheets and Operating Instructions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIE-820-Process-Calibrator-Datasheet-820-9001-Rev-F.pdf?7172371509156104321\" title=\"PIE  820  Process  Calibrator  Datasheet\" target=\"_blank\"\u003ePIE  820  Process  Calibrator  Datasheet\u003c\/a\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIE-820-Process-Calibrator-Operating-Instructions-for-Web-820-9002-Rev-G.pdf?7172371509156104321\" title=\"PIE  820  Process  Calibrator  Operating  Instructions\" target=\"_blank\"\u003ePIE  820  Process  Calibrator  Operating  Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolution, 0.00 to 24.00 mA or -25.0 to 125% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy, \u0026lt; +\/- (0.03% of full scale)\u003c\/p\u003e\n\u003cp\u003eVoltage burden, \u0026lt; 2V at 24 mA\u003c\/p\u003e\n\u003cp\u003eOverlook\/current limit protection, 25 mA nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE mA\/POWER \u0026amp; MEASUREMENT 2 WIRE TRANSMITTERS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolution, 0.00 to 24.00 mA or -25.0 to 125.0% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy, \u0026lt; +\/- (0\/03% of full scale)\u003c\/p\u003e\n\u003cp\u003eLoop compliance burden, \u0026gt; 24 DCV @ 20.00mA\u003c\/p\u003e\n\u003cp\u003eLoop drive capability, 1200 Ohms at 20 mA for 15 hrs nominal\u003c\/p\u003e\n\u003cp\u003emA 2-WIRE TRANSMITTER SIMULATION\u003c\/p\u003e\n\u003cp\u003eAccuracy, Same as source\/power \u0026amp; measure\u003c\/p\u003e\n\u003cp\u003eVoltage burden, \u0026lt; 2V at 20 mA\u003c\/p\u003e\n\u003cp\u003eOverload\/current limit protection, 24 mA nominal\u003c\/p\u003e\n\u003cp\u003eLoop voltage limits, 2 to 60 VDC (fuse-less protected fro reverse polarity connections)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDC VOLTAGE READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRange and accuracy, 0.00 to 80.00 mV, \u0026lt; +\/- (0.03% of full scale)\u003c\/p\u003e\n\u003cp\u003eInput resistance, \u0026gt; 1MOhm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE V dc\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRange and accuracy, -10.00 to 80.00 mV, \u0026lt; +\/- (0.03% of full scale), 0.00 to 10.25V, \u0026lt; +\/- (0.03% of full scale +0.005V)\u003c\/p\u003e\n\u003cp\u003eSource current, \u0026gt;24 mA\u003c\/p\u003e\n\u003cp\u003eSink current, \u0026gt;16 mA\u003c\/p\u003e\n\u003cp\u003eOutput impedance, \u0026lt;1 Ohm\u003c\/p\u003e\n\u003cp\u003eShort current duration, infinite\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMOCOUPLE SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy, +\/-(0.03% of full scale) (full scale being 80.00mV)\u003c\/p\u003e\n\u003cp\u003eCold junction compensation, +\/-0.1%C (thermistor traceable to NIST for 11 years)\u003c\/p\u003e\n\u003cp\u003eOutput impedance, \u0026lt;1 Ohm\u003c\/p\u003e\n\u003cp\u003eSource current, \u0026gt;20 mA (drives 80 mV into 10 Ohms)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMOCOUPLE READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy \u0026amp; cold junction compensation, same a t\/c source\u003c\/p\u003e\n\u003cp\u003eInput impedance, \u0026gt; 1 megohms\u003c\/p\u003e\n\u003cp\u003eOpen t\/c threshold: pulse, 10K Ohms \u0026lt; uamp pulse for 300 milliseconds (nominal)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRTD, OHMS \u0026amp; CONTINUITY READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eResistance ranges, 0.0 to 401.0 to 4010 Ohms\u003c\/p\u003e\n\u003cp\u003eAccuracy, +\/-(0.03% of full scale + 0.075 Ohms)\u003c\/p\u003e\n\u003cp\u003eExcitation current, 1.0 mA to 401 Ohms, 0.5 mA to 4010 Ohms (nominal)\u003c\/p\u003e\n\u003cp\u003eContinuity, 0.0 to 401.0 Ohms; beeps from 0.0 to 100 Ohms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRTD \u0026amp; OHMS SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy from 1 to 10.2 mA external excitation current, +\/-(0.03% of full scale + 0.075 Ohms)\u003c\/p\u003e\n\u003cp\u003eAccuracy from below 1 mA of external excitation current, +\/-(0.03% of full scale +0.075 Ohms +0.025 mV\/mA excitation current\u003c\/p\u003e\n\u003cp\u003eResistance ranges, 0.0 to 401.0 to 4010 Ohms\u003c\/p\u003e\n\u003cp\u003eAllowable excitation current range, \u0026lt;401 Ohms: 10.2 mA max; steady or pulsed\/intermittent, 402 to 4000 Ohms: 1 mA max; steady or pulsed\/intermittent\u003c\/p\u003e\n\u003cp\u003ePulsed excitation current compatibility, DC to 0.01 second pulse width\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREQUENCY SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges, 1 to 2000 CPM, 0.01 to 999.99 Hz, 0.1 to 9999.9 Hz\u003c\/p\u003e\n\u003cp\u003eAccuracy, +\/-(0.03% of full scale)\u003c\/p\u003e\n\u003cp\u003eOutput waveform, square wave, zero crossing -1.0 to +5V peak-to-peak +\/-10%\u003c\/p\u003e\n\u003cp\u003eRisetime (10 to 90% of amplitude, \u0026lt; 10 microseconds\u003c\/p\u003e\n\u003cp\u003eOutput impedance, \u0026lt;1 Ohm\u003c\/p\u003e\n\u003cp\u003eSource current, \u0026gt;1 mA rms at 20 Hz\u003c\/p\u003e\n\u003cp\u003eSort circuit duration, infinite\u003c\/p\u003e\n\u003cp\u003eOptical coupling, green LED (HZ SYNC) flashes at output frequency\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREQUENCY READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and accuracy, sames a frequency source\u003c\/p\u003e\n\u003cp\u003eAccuracy, +\/-(0.03% of full scale)\u003c\/p\u003e\n\u003cp\u003eTrigger level, 1 V rms, dc coupled\u003c\/p\u003e\n\u003cp\u003eInput impedance, \u0026gt; 1 Meg Ohm + 60 pF\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMPERATURE RANGE: \u003c\/strong\u003e-20 to 60C (-5 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTORAGE TEMPERATURE RANGE:\u003c\/strong\u003e -30 to 60C (-22 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE EFFECT:\u003c\/strong\u003e \u0026lt; +\/- 0.01%\/C of full scale\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH \u0026lt;90% (0 to 35C) non-condensing, 10% \u0026lt;RH\u0026lt; 70% (35 to 60C) non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNORMAL MODE REJECTION:\u003c\/strong\u003e 50\/60 Hz, 50 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOMMON MODE REJECTION:\u003c\/strong\u003e 50\/60 Hz, 120 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOISE:\u003c\/strong\u003e \u0026lt; \/- less significant digit from 0.1 to 10 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 5.63 x 3.00 x 1.60 in (143 x 76 x 41mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 12.1 oz (0.34 kg)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERIES:\u003c\/strong\u003e 4-AA (supplied)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY LIFE:\u003c\/strong\u003e read function \u0026gt; 20 hrs; source mA \u0026gt; 14 hrs @ 12 mA into 250 Ohms; pwr\/meas mA \u0026gt; 12 hrs at 20 mA, source V, Ohm, T\/C, RTD \u0026amp; Hz \u0026gt; 20 hrs\u003c\/p\u003e\n\u003cp\u003eL\u003cstrong\u003eOW BATTERY:\u003c\/strong\u003e 1 hr of operation left\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e over-voltage protection to 60 vrms (rated for 30 seconds), red LED indicates OVERLOAD or out of range conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e high contrast graphic LCD with 0.315\" (8.00 mm) LED backlight for use in low lit areas\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12583458471978,"sku":"CL-PI-820","price":3113.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIECAL_820_displaying_TC_with_connection_icons.jpg?v=1535204991"},{"product_id":"pie-334-4-20-ma-loop-calibrator","title":"334, 4-20 mA Loop Calibrator","description":"\u003cul\u003e\n\u003cli\u003eEasy To Use, Dependable Milliamp Loop Calibrator\u003c\/li\u003e\n\u003cli\u003eSource Milliamps\u003c\/li\u003e\n\u003cli\u003eCalibrate Using Loop Power\u003c\/li\u003e\n\u003cli\u003eRead Loop Current\u003c\/li\u003e\n\u003cli\u003ePower and Measure 2 Wire Transmitters\u003c\/li\u003e\n\u003cli\u003eRead DC Volts\u003c\/li\u003e\n\u003cli\u003eComes With Rubber Boot, NIST Certificate, Test Lead w\/Alligator Clips, Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the 334 you can check, calibrate and measure all your current signal instruments in a 4 to 20 milliamp DC loop. The PIE 334 can be used at any access point in your loop. Source and read 0.00 to 24.00 mA, simulate a 2 wire transmitter or use the meter to simultaneously power your 2 wire transmitter and measure its output. Calibrate in confidence: accurate to +\/-0.025% of span at 4.00 \u0026amp; 20.00 EZ-CHECK outputs.\u003c\/p\u003e\n\u003cp\u003eSource milliamps: calibrate recorders, digital indicators, stroke valves or any instruments that get their input from a 4 to 20 mA loop. Easily set any value quickly to within 0.01 mA with the adjustable digital potentiometer DIAL or use the preset 4.00 mA (0.0%) and 20.00 mA (100%) EZ-CHECK settings.\u003c\/p\u003e\n\u003cp\u003eWith the 334 you can calibrate using loop power. Check loop wiring and receivers by using the 334 in place of a 2 wire transmitter. PIE 334 uses any loop power from 2 to 100 V DC.\u003c\/p\u003e\n\u003cp\u003eRead loop power with the 334. Check controller outputs or measure the milliamp signal anywhere in the loop. The 334 measures 0.00 to 52.00 mA (-25.0 to 300.0%) signals with greater accuracy than a typical multimeter.\u003c\/p\u003e\n\u003cp\u003ePower and measure 2 wire transmitters with the 334. You can simultaneously  output 24V DC to power any and all devices in a process loop using the internal batteries and internal switching power supply while measuring the output of a 2 wire transmitter with any other loop meters.\u003c\/p\u003e\n\u003cp\u003eRead DC volts with the 334. You can measure from -99.99 to +99.99 VDC with 0.01 volt resolution. Use 334 to check loop power supplies, I\/V converters, 1 to 5 volt signals and other voltages making it unnecessary to carry a multimeter.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on \u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003cstrong\u003e\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-334\u003c\/td\u003e\n\u003ctd\u003ePIE 334, 4-20 mA Loop Calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDatasheets and User Manuals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-334-4-20-mA-Loop-Calibrator-Datasheet-Rev-H.pdf?17822458146514850831\" title=\"PIECAL 334 Datasheet\"\u003ePIECAL 334 Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-334-4-20-mA-Loop-Calibrator-Operating-Instructions-334-9002-Rev-E.pdf?17822458146514850831\" title=\"PIECAL 334 Operating Instructions\"\u003ePIECAL 334 Operating Instructions\u003c\/a\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolution, 0.00 to 52.00 mA or -25.0 to 300% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy below 24.010 mA, \u0026lt; +\/-(0.05% of 24.00 mA) (+\/-0.01 mA), accuracy above 24.010mA, \u0026lt; +\/-(0,05% of 52.00 mA) (+\/-0.3 mA)\u003c\/p\u003e\n\u003cp\u003eVoltage burden, \u0026lt; 2V at 50 mA\u003c\/p\u003e\n\u003cp\u003eOverload\/current limit, 54 mA nominal\u003c\/p\u003e\n\u003cp\u003eBattery life, \u0026gt;125 hrs nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE\/POWER \u0026amp; MEASURE 2 WIRE TRANSMITTERS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolution, 0.00 to 24.00 or -25.0 to 125.0% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy EZ-CHECKS at 4 \u0026amp; 20 mA, \u0026lt; +\/- (0.025% of span at 4 mA \u0026amp; 20 mA) (+\/-0.005mA), EZ-CHECKS at 0.000 to 24.000 mA, \u0026lt; +\/- (0.05% of 24 mA span) (+\/-0.012mA)\u003c\/p\u003e\n\u003cp\u003eNoise, \u0026lt; +\/- 1\/2 least significant digit\u003c\/p\u003e\n\u003cp\u003eTemperature effect, \u0026lt; +\/- 0.005% C of FS\u003c\/p\u003e\n\u003cp\u003eLoop compliance voltage, \u0026gt; 24 DCV @ 20.00 mA\u003c\/p\u003e\n\u003cp\u003eLoop drive capability, 1200 Ohms at 20 mA for 15 hrs nominal\u003c\/p\u003e\n\u003cp\u003eBattery life, \u0026gt; 30 hrs at 12 mA nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2-WIRE TRANSMITTER SIMULATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy, sames as source\/power \u0026amp; measure\u003c\/p\u003e\n\u003cp\u003eVoltage burden, \u0026lt; 2V at 20 mA\u003c\/p\u003e\n\u003cp\u003eOverload\/current limit protection, 24 mA nominal\u003c\/p\u003e\n\u003cp\u003eLoop voltage limits, 2 to 100 VDC (fuse-less protected from reverse polarity connections)\u003c\/p\u003e\n\u003cp\u003eBattery life, \u0026gt; 125 hrs nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVOLTAGE READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRange and resolutions, -99.99 to +99.99 VDC full span (FS)\u003c\/p\u003e\n\u003cp\u003eAccuracy, \u0026lt; +\/-0.05% of FS\u003c\/p\u003e\n\u003cp\u003eTemperature effect, \u0026lt; +\/- 100 ppm\/C of FS\u003c\/p\u003e\n\u003cp\u003eInput resistance, \u0026gt; 2 MOhms\u003c\/p\u003e\n\u003cp\u003eBattery Life, \u0026gt; 125 hrs nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMPERATURE RANGE:\u003c\/strong\u003e -20 to 60C (-5 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTORAGE TEMPERATURE RANGE:\u003c\/strong\u003e -30 to 60C (-22 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH \u0026lt;90% (0 to 35C) non-condensing,10% \u0026lt;RH \u0026lt;70% (35 to 60C) non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 5.63 x 3.00 x 1.60 in (143 x 76 x 41mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 12.1 oz (0.34 kg) including boot and 4-AA  batteries\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLOW BATTERY:\u003c\/strong\u003e Low battery indication with nominal 1 hr of operation left\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e Over-voltage protection to 135 vrms (rated for 30 seconds) or 240 vrms (rated for 15 seconds\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e High contrast LCD with 0.315\" (8.0 mm) high digits\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12593310990378,"sku":"CL-PI-334","price":996.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIECAL_334_Rev_B_with_Backlight.jpg?v=1535204765"},{"product_id":"pie-541-frequency-process-calibrator-w-totalizer-function","title":"541 Frequency Process Calibrator w\/Totalizer Function","description":"\u003cul\u003e\n\u003cli\u003eFrequency Read \u0026amp; Source Functions, Accuracy +\/- 0.005% of Range\u003c\/li\u003e\n\u003cli\u003eCalibrate Totalizers, Output Pulses from 1 to 100 Minutes\u003c\/li\u003e\n\u003cli\u003eGate Trigger Indicator, LED Flashes in Synch w\/Output Frequency\u003c\/li\u003e\n\u003cli\u003eFull 5 Digit Display, True +\/-0.005% of Range Accuracy\u003c\/li\u003e\n\u003cli\u003eEZ_Dial Knob, Push the Knob for Easy Change of Speed of Test Point\u003c\/li\u003e\n\u003cli\u003eEZ-Check Switch for Stop Watch Style Accurate Totalizer Measurements\u003c\/li\u003e\n\u003cli\u003e240 VAC Tolerant for Fuse-less Protection From Misuse\u003c\/li\u003e\n\u003cli\u003eSuperior Battery Life of 45 Hrs Under Typical Usage\u003c\/li\u003e\n\u003cli\u003eComes with Manual, NIST Certficate, Carrying Case, CE Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 541 is designed for calibration, testing and diagnosing turbine meters, frequency counters, vibration systems, tachometers, vortex shedders, integrators and any frequency device. Save hours of time compared to other calibration methods. When calibrating a totalizer, the 541 eliminates the need of a stop watch. Set the number of pulses and number of minutes required and it automatically stops when the selected number of pulses has been sent to the totalizer. The 541 has a handy LED indicator showing gate time for easy trigger level adjustment. The LED also pulses with the frequency output for calibration of optical pickups.\u003c\/p\u003e\n\u003cp\u003eThe 541 has 5 ranges from 1 CPH to 20.000KHz for source and read. Totalizer inputs\/outputs are from 1 to 99999 pulses in 1.0 to 100 minutes, and read a wide range of frequencies and wave forms from 50 mV to 120V. The 541 can source sine and square waves with zero based or zero crossing and has an adjustable output amplitude from 100 mV to 12 V peak-to-peak.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003cstrong\u003e\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-541\u003c\/td\u003e\n\u003ctd\u003ePIE 541 Frequency Process Calibrator w\/Totalizer Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e  Datasheets and Operating Instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-541-Frequency-Calibrator-Datasheet-541-9001-Rev-D.pdf?14031769941083994834\" title=\"PIECAL  541  Frequency  Calibrator  Datasheet\"\u003ePIECAL  541  Frequency  Calibrator  Datasheet\u003c\/a\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-541-Frequency-Calibrator-Operating-Instructions-541-9002-Rev-D.pdf?14031769941083994834\" title=\"PIECAL 541 Frequency Calibrator Operating Instructions\"\u003ePIECAL 541 Frequency Calibrator Operating Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOMMON SPECS FOR ALL FREQUENCY MODES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFrequency range, 1 CPH to 20.000Khz\u003c\/p\u003e\n\u003cp\u003eAccuracy, +\/- 0.005% of range\u003c\/p\u003e\n\u003cp\u003eTemperature effect, \u0026lt; 10ppm\/C of range\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREQUENCY RANGE SPECS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1, 1  CPH\u0026lt; CPH range \u0026lt; 20000 CPH\u003c\/p\u003e\n\u003cp\u003e2, 0.1 CPM (0.0167Hz) \u0026lt; CPM range \u0026lt; 2000.0 CPM (33.33Hz)\u003c\/p\u003e\n\u003cp\u003e3, 0.01Hz \u0026lt; Hz \u0026lt; 200.00Hz\u003c\/p\u003e\n\u003cp\u003e4, 0.1Hz \u0026lt; Hz range \u0026lt; 2000.0Hz\u003c\/p\u003e\n\u003cp\u003e5, 0.001KHz \u0026lt; KHz \u0026lt; 20.000KHz\u003c\/p\u003e\n\u003cp\u003e6, totalizer inputs\/outputs from 1 to 99999 counts in 0.1 mins to 100.0 mins\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD INPUTS SPECS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRead, x1 attenuation range: 0.1Vpk to 12Vpk, x10 attenuation range: 1 Vpk to 120V peak - limit of attneuation is 120Vpk\u003c\/p\u003e\n\u003cp\u003eInput impedance, \u0026gt; 1 Meg Ohm + 100pF\u003c\/p\u003e\n\u003cp\u003eAdjustable signal attenuation, adjustable trigger level wit X1 and x10 attenuation ranges\u003c\/p\u003e\n\u003cp\u003eBattery life, 24 hrs typical\u003c\/p\u003e\n\u003cp\u003eFuse-less protection, 240Vrms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWAVE FORMS SOURCES SPECS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOutput current, \u0026gt; 6mApp at 12Vpp output, 20KHz\u003c\/p\u003e\n\u003cp\u003eOutput impedance, \u0026lt; 25Ohms\u003c\/p\u003e\n\u003cp\u003eSquare wave: zero crossing, zero based: selectable\u003c\/p\u003e\n\u003cp\u003eSquare wave: rise\/fall time: \u0026lt; 0.0001% of output Vpk per second\u003c\/p\u003e\n\u003cp\u003eSquare wave: frequency jitter: \u0026lt; 0.5LSB of frequency range\u003c\/p\u003e\n\u003cp\u003eSquare range: duty cycle: 50% +\/- 2%\u003c\/p\u003e\n\u003cp\u003eSine wave: offset and zero crossing symmetry: \u0026lt;+\/- 10% of Vpk output amplitude setting\u003c\/p\u003e\n\u003cp\u003eSine wave: amplitude adjustment: 100mV \u0026lt; nominal output \u0026lt; 12Vpp +\/-% of setting\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12602520109098,"sku":"CL-PI-541","price":2648.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIE_Model_541_Photo.jpg?v=1535204868"},{"product_id":"pie-525b-rtd-thermcouple-calibrator","title":"525B RTD\/Thermocouple Calibrator","description":"\u003cul\u003e\n\u003cli\u003eCalibrate T\/C Instruments to 0.1 \u0026amp; 0.01 F\/C for J\/K\/T\/E\/R\/S\/B\/N\/G\/C\/D\/L\/U\/P: -13.000 to 80.000 mV\u003c\/li\u003e\n\u003cli\u003eCalibrate RTD Instruments to 0.1 \u0026amp; 0.01 F\/C for Pt 10\/50\/100\/200\/500\/1000 Ohms(3850), Pt 100 Ohm (alpha=3902,3916,3926), Cu 10\/50 Ohm and Ni 120 Ohm\u003c\/li\u003e\n\u003cli\u003eCalibrate w\/Confidence, Resolution to 0.01 F\/C to 0.2C, Cold Junction Sensor Accurate to 0.05C\u003c\/li\u003e\n\u003cli\u003eVerify Heat Treating Uniformity Survey Recorders \u0026amp; Perform System Accuracy\u003c\/li\u003e\n\u003cli\u003eTroubleshoot RTD Sensors \u0026amp; Instruments w\/Automatic Detection of 2\/3\/4 Wire Connections when Individual Wire are Open\u003c\/li\u003e\n\u003cli\u003eFaster Calibrations \u0026amp; Easily Switch T\/C and RTD Types \u0026amp; Scale\u003c\/li\u003e\n\u003cli\u003eVerify Resistance, Cold Junction Temperature \u0026amp; Output\u003c\/li\u003e\n\u003cli\u003eComes w\/NIST Cert, Rubber Boot, Carrying Case, mA\/V Test Lead Set, RTD Wire Kit, Batteries, Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith the 525B you can check and calibrate all your thermocouple and RTD instruments to 0.1 \u0026amp; 0.01 F\/C, and measure your temperature sensors. And the 525B works with the thermocouples you normally use, or calibrate from -13.0000 to +80.0000mV. Or the PIE  525B works with the RTDs you normally use, and calibrate from 0.000 to 400.000 and 0.00 to 4000.00 Ohms (for RTDs the fixed or pulsed sensor current is measured by the calibrator)\u003c\/p\u003e\n\u003cp\u003eYou get fast calibration and automatic stepping with the 525B. Easily set any value quickly to within 0.1 or 0.01C with the adjustable digital potentioemeter DIAL plus store any 3 temperatures for instant recall with the EZ-CHECK switch. Choose between 2, 3, 5, or 11 steps and ramp to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select step time from 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, 60 seconds.\u003c\/p\u003e\n\u003cp\u003eMeasure thermocouple and RTD sensors and troubleshoot sensor connections with the 525B. Probes can be measured to 0.1 or 0.01 C\/F accuracy. And the internal cold junction thermisitor is accurate to +\/-0.05C and is traceable to NIST.\u003c\/p\u003e\n\u003cp\u003eThe sensor in the 525B is thermally bonded to an isothermal mass which includes brass blocks with screw terminal for connection of bare t\/c wires along with a mini t\/c connector for fast connections. This circuitry uses an extremely stable voltage reference and low drift components which makes the 525B more accurate than other handheld and most benchtop t\/c calibrators.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on and \u003cstrong\u003eADD TO CART\u003c\/strong\u003e \u003c\/em\u003ebutton\u003cstrong\u003e\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-525B\u003c\/td\u003e\n\u003ctd\u003ePIE 525B RTD\/Thermocouple Calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e Datasheets and Operating Instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-510B-511B-RTD-Simulator-Datasheet-510B-9001-Rev-C-1.pdf?2447033753239084722\" title=\"PIECAL 510B RTD Simulator Datasheet 510B 9001 Rev C 1.pdf\" target=\"_blank\"\u003ePIECAL 510B Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIECAL-510B-511B-RTD-Simulator-Operating-Instructions-510B-9002-Rev-D.pdf?2447033753239084722\" title=\"PIECAL 510B  RTD Simulator Operating Instructions\" target=\"_blank\"\u003ePIECAL 510B Operating Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMOCOUPLE SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy, +\/-(0.008% of setting + 0.006 mV)\u003c\/p\u003e\n\u003cp\u003eCold Junction, +\/- 0.09%F (+\/-0.05% C) - Thermistor traceable to NIST for 11 yrs\u003c\/p\u003e\n\u003cp\u003eOutput Impedance, \u0026lt; 0.3 Ohms\u003c\/p\u003e\n\u003cp\u003eSource Current, \u0026gt; 10 mA (drives 80 mV into 10 Ohms)\u003c\/p\u003e\n\u003cp\u003eRMS Noise, \u0026lt; +\/- 0.0005 mV from 0.1 to Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMOCOUPLE READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy, +\/-(0.008% of reading + 0.006 mV)\u003c\/p\u003e\n\u003cp\u003eCold Junction, +\/- 0.09F (+\/-0.05%C) - Thermistor traceable to NIST for 11 yrs\u003c\/p\u003e\n\u003cp\u003eInput Impedance, \u0026gt; 10 Megaohms\u003c\/p\u003e\n\u003cp\u003eOpen Thermocouple, Threshold: 10.000 Ohms nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRTD and OHMS SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 \u0026amp; 4 wire accuracy from 1 to 10.2 mA external excitation current: +\/-(0.015% of setting + 0.05 Ohms)\u003c\/p\u003e\n\u003cp\u003e3 \u0026amp; 4 wire accuracy below 1 mA of external excitation current: Add (0.025mV)\/mA excitation current, to 90 days \u0026amp; 1 year accuracy\u003c\/p\u003e\n\u003cp\u003e2 wire accuracy:  add 0.1 Ohms to 3 \u0026amp; 4 wire accuracy\u003c\/p\u003e\n\u003cp\u003eResistance ranges: 400 Ohm range: 0.00 to 401.00 \u0026amp; 0.000 to 401.00; 4000 Ohm range: 0.00 to 4010.0 \u0026amp; 0.00 to 4010.00\u003c\/p\u003e\n\u003cp\u003eRMS noise: 400 Ohm range \u0026lt; +\/- 0.005 Ohms from 0.1 to 10 Hz; 4000 Ohm range: \u0026lt; +\/- 0.05 Ohms from 0.1 to 10 Hz\u003c\/p\u003e\n\u003cp\u003eAllowable excitation current range: 400 Ohm range: 10.2 mA max, steady or pulse\/intermittent; 4000 Ohm range: 1 mA max, steady or pulse\/intermittent\u003c\/p\u003e\n\u003cp\u003ePulse excitation current compatibility: DC to 0.01 second pulse width\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRTD AND OHMS READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eResistance ranges: same as RTD and Ohms source\u003c\/p\u003e\n\u003cp\u003e3 \u0026amp; 4 wire accuracy: +\/-(0.015% of reading + 0.05 Ohms)\u003c\/p\u003e\n\u003cp\u003e2 wire accuracy:  +\/-(0.015% of reading + 0.15 Ohms)\u003c\/p\u003e\n\u003cp\u003eExcitation current: 0.9 mA to 401 Ohms, 0.4 mA to 4010 Ohms (nominal)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVOLTAGE SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolutions: -13.000  to 80.000 mV \u0026amp; -13.0000 to 80.0000 mV\u003c\/p\u003e\n\u003cp\u003eAccuracy: +\/-(0.008% of setting + 0.006 mV)\u003c\/p\u003e\n\u003cp\u003eSource current: \u0026gt; 10 mA\u003c\/p\u003e\n\u003cp\u003eOutput impedance: \u0026lt; 0.3 Ohm\u003c\/p\u003e\n\u003cp\u003eRMS noise: \u0026lt; +\/- 0.0005 mV from 0.1 to 10 Hz\u003c\/p\u003e\n\u003cp\u003eShort circuit duration: infinite\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMPERATURE RANGE:\u003c\/strong\u003e -20 to 60C (-5 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTORAGE TEMPERATURE RANGE:\u003c\/strong\u003e -30 to 60C (-22 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE EFFECT:\u003c\/strong\u003e \u0026lt; +\/-50 ppm\/C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH\u0026lt;90% (0 to 35C) non-condensing; 10% \u0026lt;RH\u0026lt;70% (35 to 60C) non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNORMAL MODE REJECTION:\u003c\/strong\u003e 50\/60 Hz, 50 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOMMON MODE REJECTION:\u003c\/strong\u003e 50\/60 Hz, 120 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 5.63 x 3.00 x 1.60 in (143 x 76 x 41 mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 12.1 oz (0.34 kg) including boot and  4-AA batteries\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY LIFE:\u003c\/strong\u003e 50 hrs with low battery indication (1 hr of operating left)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e Overvoltage protection to 60 vrms (\u003cstrong\u003erated for 30 seconds); Red LED indicates OVERLOAD or out of range conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e High contrast LCD. LED backlight for use in low lit areas\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12610299002922,"sku":"CL-PI-525B","price":2594.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIE_525B_Displaying_Read_4_Wire_RTD_High_Res.jpg?v=1535204931"},{"product_id":"pie-311-plus-diagnostic-rtd-milliamp-calibrator","title":"Diagnostic RTD\/Milliamp Calibrator w\/Patented RTD Wire Detection, Model 311-PLUS by PIE","description":"\u003cul\u003e\n\u003cli\u003eThe ONLY 2-in-1 Full Function RTD\/Milliamp Calibrator on the Market\u003c\/li\u003e\n\u003cli\u003eProtects Instruments \u0026amp; Technicians From Potentially Dangerous Catastrophic Failures Due to Hidden Loop Probelms\u003c\/li\u003e\n\u003cli\u003eCompatible w\/All Process Instruments\u003c\/li\u003e\n\u003cli\u003eTroubleshoot RTD Sensors and Loop Problems\u003c\/li\u003e\n\u003cli\u003eEasiest to Use \u0026amp; Half the Size of the Closest Competitor\u003c\/li\u003e\n\u003cli\u003eCalibrate Directly in C\/F, No Need to Carry Around a Decade Box\/RTD Tables\u003c\/li\u003e\n\u003cli\u003eFast Calibration w\/Automatic Stepping\u003c\/li\u003e\n\u003cli\u003eMeasure RTD Sensors\u003c\/li\u003e\n\u003cli\u003eWith the Built-In Milliamp Calibrator You Can Check, Calibrate \u0026amp; Measure All Current Signal Instruments in a 4-20 mA Loop\u003c\/li\u003e\n\u003cli\u003eComes With NIST Cert, Rubber Boot, Carrying Case, 2 Red \u0026amp; 2 Black Leads w\/Banana to Spade Lugs\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #274e13;\"\u003e\u003cstrong\u003eShips In 1-2 Days For Fast and FREE Delivery\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 311-PLUS is the only calibrator that combines all the functions of a diagnostic milliamp calibrator with the accuracy of a laboratory RTD calibrator. You can quickly diagnose ground fault and current leakage often caused by water in conduits and junction boxes with patented loop diagnostic technology (patent # 7,248,058).\u003c\/p\u003e\n\u003cp\u003eNo competitor's calibrator is compatible with as many process instruments. Connect directly to RTD inputs of smart transmitters, PLCs, DCS and multichannel recorders and verify their outputs or displays. You can troubleshoot sensor connections and find broken wires with the patented technology. Connect your 2, 3, 4 wire RTDs and the PIE 311-PLUS automatically detects the connections. Secondary display shows the resistance value corresponding to the RTD temperature.\u003c\/p\u003e\n\u003cp\u003eWhen you have a RTD input problem that is difficult to diagnose, the 311-PLUS makes it easy. When you connect the meter directly to the RTD sensor it will indicate on the display which wires are connected. This quickly points out if there is a problem with the wiring or with the sensor itself. If no problem is found with the sensor connect the  311-PLUS to the sensor input connections on the instrument to see if it is working properly. Secondary displays show you the resistance value of the RTD plus the magnitude and direction of the excitation current used by the instrument to measure the RTD sensor. If no excitation current is detected then there is a problem with the instrument.\u003c\/p\u003e\n\u003cp\u003eThe 311-PLUS allows for fast calibration with automatic output stepping. You can choose between 2, 3, 5, 11 and 21 steps to automatically increment the  outputs in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 9, 10, 15, 20, 25, 30, 60 seconds.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page and then click  on \u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePART NUMBER\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-311-PLUS\u003c\/td\u003e\n\u003ctd\u003ePIE 311-PLUS Diagnostic RTD\/Milliamp Calibrator w\/Patented RTD Wire Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e Datasheets and Operating Instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/311Plus-9001-Rev-B-PIE-311Plus-Diagnostic-RTD-and-Milliamp-Calibrator-Datasheet.pdf?4302672379852369759\" title=\"PIE-311Plus Diagnostic RTD and Milliamp Calibrator Datasheet\"\u003eCL-PI-311-PLUS Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/311-Plus-9002-Rev-A-PIE-311Plus-Diagnostic-RTD-and-mA-Calibrator-Operating-Instructions.pdf?4302672379852369759\" title=\"PIE 311Plus Diagnostic RTD and mA Calibrator Operating Instructions\"\u003eCL-PI-311-PLUS Operating Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e (unless otherwise noted, all specs are rated a nominal 25C, 70% RH for 1 year from calibration)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolution: 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy: \u0026lt; +\/-(0.02% of reading + 0.003 mA)\u003c\/p\u003e\n\u003cp\u003eVoltage burden: \u0026lt; 2V at 24 mA\u003c\/p\u003e\n\u003cp\u003eOverload\/current limit protection: 25 mA nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE mA\/POWER \u0026amp; MEASURE 2 WIRE TRANSMITTERS \u0026amp; PW\/RM LEAK\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges \u0026amp; resolution: 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy: \u0026lt; +\/-(0.02% of reading + 0.003 mA)\u003c\/p\u003e\n\u003cp\u003eLoop compliance voltage: \u0026gt; 24 DCV @ 20.00 mA\u003c\/p\u003e\n\u003cp\u003eLoop drive capability: 1200 Ohms at 20 mA for 15 hrs nominal: 950 Ohms w\/Hart Resistor or leak detection running\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003emA 2-WIRE TRANSMITTER SIMULATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy: Same as source\/power \u0026amp; measure\u003c\/p\u003e\n\u003cp\u003eVoltage burden: \u0026lt; 2V at 20 mA\u003c\/p\u003e\n\u003cp\u003eOverload\/current limit protection: 24 mA nominal\u003c\/p\u003e\n\u003cp\u003eLoop voltage limits: 2 to 60 VDC (fuse-less protected from reverse polarity connections)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD OHMS \u0026amp; RTD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 \u0026amp; 4-wire accuracy: +\/-(0.015% of reading + 0.05 Ohms)\u003c\/p\u003e\n\u003cp\u003e2-wire accuracy: +\/-(0.015% of reading + 0.05 Ohms)\u003c\/p\u003e\n\u003cp\u003eResistance ranges: 0.00 to 401.00, 0.0 to 4010.0 Ohms\u003c\/p\u003e\n\u003cp\u003eExcitation current: 0.9 mA to 401 Ohms, 0.4 mA to 4010 Ohms (nominal)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE OHMS \u0026amp; RTD\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3 \u0026amp; 4-wire accuracy from 1 to 10.2 mA external excitation current: +\/-(0.015% of reading + 0.05 Ohms)\u003c\/p\u003e\n\u003cp\u003eBelow 1 mA of external excitation current: +\/-(0.015% of Rdg + 0.025 mv\/mA excitation current + 0.05 Ohms\u003c\/p\u003e\n\u003cp\u003e2-wire accuracy: Add 0.1 Ohms to 3 \u0026amp;4-wire accuracy\u003c\/p\u003e\n\u003cp\u003eResistance ranges: 0.00 to 401.00, 0.0 to 4010 Ohms\u003c\/p\u003e\n\u003cp\u003eAllowable excitation current range: 0 to 400 Ohms: 10.2 mA max; steady or pulsed\/intermittent, 401 to 4000 Ohms: 1 mA max: steady or pulsed\/intermittent\u003c\/p\u003e\n\u003cp\u003ePulsed excitation current compatibility: DC to o.o1 second pulse width\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMPERATURE RANGE:\u003c\/strong\u003e -25 to 60C (-10 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH \u0026lt;90% (0 to 35C) non-condensing, 10% \u0026lt;RH \u0026lt;70% (35 to 60C) non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE DRIFT:\u003c\/strong\u003e +\/- 0.01% of span outside 23C +\/-10C (73C +\/- 18F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 5.63 x 3.00 x 1.60 in ( 143 x 76 x 41 mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 12.1 ox, 0.34 kg (including boot \u0026amp; 4-AA batteries)\u003c\/p\u003e\n\u003cp\u003eBATTERY LIFE: 25 hrs RTD, 8 hrs Milliamp\u003c\/p\u003e\n\u003cp\u003eISOLATION VOLTAGE: 60V rms between all miliamp functions and source\/read RTD\/Ohms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOMINAL MODE REJECTION:\u003c\/strong\u003e 50\/60 Hz, 50 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOMMON MODE REJECTION:\u003c\/strong\u003e 50\/60 Hz, 120 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLOW BATTERY WARNING:\u003c\/strong\u003e Low battery indication with 1 hr of operation left\u003c\/p\u003e\n\u003cp\u003eP\u003cstrong\u003eROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e Over-voltage protection to 60V dc (rated for 30 seconds)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e High contrast LCD display. LED backlight for use in low lit areas\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12618141728810,"sku":"CL-PI-311-PLUS","price":2738.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIE_311Plus_RTD_PWRM_HART.jpg?v=1535204600"},{"product_id":"pie-830-process-calibrator","title":"830 Multifunction Diagnostic Process Calibrator","description":"\u003cul\u003e\n\u003cli\u003eMultifunction Dual Channel Process Calibrator: mA, V, T\/C, OHMS, RTD, Hz, pH, Pressure\u003c\/li\u003e\n\u003cli\u003eFirst Multifunction Calibrator w\/5 Troubleshooting Tools Plus a Universal Transmitter\u003c\/li\u003e\n\u003cli\u003eDetect Hidden Loop Problems w\/Patented Current Leak Detection Technology\u003c\/li\u003e\n\u003cli\u003eCheck All Loop Parameters at Once with the LoopScope\u003c\/li\u003e\n\u003cli\u003eAutomatically Detect 2,3,4-Wire RTDs\u003c\/li\u003e\n\u003cli\u003eSwap Out Faulty Transmitters to Diagnose Control Issues\u003c\/li\u003e\n\u003cli\u003eTroubleshoot Wiring Problems Without a Multimeter\u003c\/li\u003e\n\u003cli\u003eUse as a Milliamp and Voltage Calibrator\u003c\/li\u003e\n\u003cli\u003eCalibrate Directly in C\/F\u003c\/li\u003e\n\u003cli\u003eCheckout Flow and Vibration Systems\u003c\/li\u003e\n\u003cli\u003eSimulate pH Probes into Transmitters \u0026amp; Analyzers\u003c\/li\u003e\n\u003cli\u003eMeasure Temperature Sensors, Frequency Pickups, Loop Currents, Voltage Levels \u0026amp; Pressure\u003c\/li\u003e\n\u003cli\u003eComes with NIST Cert, Rubber Boot, Carrying Case, Manual, Batteries, mV\/RTD Test Lead Set, RTD Wire Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGet more tools in a smaller calibrator. Carry eight single function calibrators plus a milliamp calibrator with loop supply plus a loop trouble shooter in the palm of your hand.\u003c\/p\u003e\n\u003cp\u003eThe 830 is more than a multifunction calibrator. It is also a loop detective that is able to diagnose common problems that other test equipment just can't find. Have a flooded junction box or unknown ground faults? The 830 diagnostic technology will detect it. Or use the exclusive LoopScope to see at a glance all the parameters - milliamps, voltage and resistance - in the loop.\u003c\/p\u003e\n\u003cp\u003eStop throwing away perfectly good transmitters only to find the problem is somewhere else in the loop. Setup the 830 as an isolated universal transmitter and turn on the Loop Diagnostics. The display will tell you exactly the sensor input, the current output and if there is any uncontrolled current in the loop due to a ground fault, corrosion bridge or moisture. If the control system sees no problem when the 830 is acting as a transmitter then you can replace the faulty transmitter. With RTDs the 830 automatically detects which of the 2,3, or 4 wires are connected and unbroken quickly alerting you to a sensor problem.\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page then click on and \u003cstrong\u003eADD TO CART \u003c\/strong\u003e\u003c\/em\u003ebutton\u003cstrong\u003e\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e PART NUMBER\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL-PI-830\u003c\/td\u003e\n\u003ctd\u003ePIE 830 Multifunction Diagnostic Process Calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e Datasheets and Operating Instructions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIE-830-Process-Calibrator-Datasheet.pdf?2109787918191528438\" title=\"PIE 830 Datasheet\"\u003ePIE 830 Datasheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/PIE-830-Op-Inst.pdf?2109787918191528438\" title=\"PIE 830 Operating Instructions\"\u003ePIE 830 Operating Instructions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eREAD mA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolution: 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy: \u0026lt; +\/-(0\/02% of reading + 0.003 mA)\u003c\/p\u003e\n\u003cp\u003eVoltage burden: \u0026lt; 2C at 24 mA\u003c\/p\u003e\n\u003cp\u003eOverload\/current limit protection: 24 mA nominal\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE mA\/POWER \u0026amp; MEASURE 2-WIRE TRANSMITTERS \u0026amp; PWRM LEAK\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resistances: 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA\u003c\/p\u003e\n\u003cp\u003eAccuracy: \u0026lt; +\/-(0.02% of reading + 0.003 mA)\u003c\/p\u003e\n\u003cp\u003eLoop compliance voltage: \u0026gt; 24 DCV @ 20.00 mA\u003c\/p\u003e\n\u003cp\u003eLoop drive capability: 1200 Ohms at 20 mA for 15 hours nominal\u003c\/p\u003e\n\u003cp\u003eLoop drive capability: 1200 Ohms at 20 mA for 15 hrs nominal; 950 Ohms with Hart Resistor or leak detection running\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003emA 2-WIRE TRANSMITTER SIMULATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy: same as source\/power \u0026amp; measure\u003c\/p\u003e\n\u003cp\u003eVoltage burden: \u0026lt; 2V at 20 mA\u003c\/p\u003e\n\u003cp\u003eOverload\/current limit protection: 24 mA nominal\u003c\/p\u003e\n\u003cp\u003eLoop voltage limits: 2 to 60 VDC (fuse-less protected from reverse polarity connections)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVOLTAGE READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRange and resolution: +\/-99.999 mV, +\/-999.99 mV, 0 to 10.250V, 0.00 to 60.00V DC\u003c\/p\u003e\n\u003cp\u003eAccuracy: \u0026lt; +\/-(0.02% of reading + 0.01% full scale)\u003c\/p\u003e\n\u003cp\u003eInput resistance: \u0026gt; 1MOhm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSOURCE V DC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and resolution: -20.000 to 99.000 mV, 500.00 to 999.99 mV, 0.000 to 10.250V\u003c\/p\u003e\n\u003cp\u003eAccuracy: \u0026lt; +\/-(0.02% of reading + 0.01%full scale)\u003c\/p\u003e\n\u003cp\u003eSource current: \u0026gt; 20 mA\u003c\/p\u003e\n\u003cp\u003eSink current: \u0026gt; 16 mA\u003c\/p\u003e\n\u003cp\u003eOutput impedance: \u0026lt; 1 Ohm\u003c\/p\u003e\n\u003cp\u003eShort circuit duration: infinite\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003epH SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy in mV: \u0026lt; +\/-(0.02% of reading in Mv + 0.1 mV)\u003c\/p\u003e\n\u003cp\u003eAccuracy in pH: \u0026lt; =\/- 0.003 pH @ 25C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMOCOUPLE SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy: \u0026lt; +\/-(0.02% of reading + 0.01 mV)\u003c\/p\u003e\n\u003cp\u003eCold junction compensation: +\/- 0.05C - thermistor traceable to NIST for 11 years\u003c\/p\u003e\n\u003cp\u003eOutput impedance: \u0026lt; 1 Ohm\u003c\/p\u003e\n\u003cp\u003eSource current: \u0026gt; 20 mA (drives 80 mV into 10 Ohms)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTHERMOCOUPLE READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAccuracy \u0026amp; cold junction compensation: sames as thermocouple source\u003c\/p\u003e\n\u003cp\u003eInput impedance: \u0026gt; 1 Megohms\u003c\/p\u003e\n\u003cp\u003eOpen t\/c threshold: Pulse: 10K Ohms; \u0026lt;5 uamp puse for 300 milliseconds (nominal)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRTD, OHMS \u0026amp; CONTINUITY READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eResistance ranges: 0.00 to 401.00, 0.0 to 4010 Ohms\u003c\/p\u003e\n\u003cp\u003eAccuracy: +\/-(0.025% of reading + 0.065 Ohms)\u003c\/p\u003e\n\u003cp\u003eExcitation current: 1.0 mA to 401 Ohms, 0.5 mA to 4010 Ohms (nominal)\u003c\/p\u003e\n\u003cp\u003eContinuity: 0.0 to 401.0 Ohms; beeps from 0.0 to 100 Ohms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRTD \u0026amp; OHMS SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e3-4 Wire Accuracy from 1 to 10.2 mA external excitation current: +\/-(0.025% of reading + 0.075 Ohms\u003c\/p\u003e\n\u003cp\u003eBelow 1 mA of external excitation current: +\/-(0.025% of reading + 0.075 Ohms + 0.025 mV\/mA excitation current)\u003c\/p\u003e\n\u003cp\u003e2-Wire Accuracy: add 0.1 Ohms to 3-4 wire accuracy\u003c\/p\u003e\n\u003cp\u003eResistance ranges: 0.00 to 401.00 to 4010.0 Ohms\u003c\/p\u003e\n\u003cp\u003eAllowable excitation current range: \u0026lt;401 Ohms: 10.2 mA max; steady or pulse\/intermittent, 401 to 4000 Ohms: 1 mA max; steady or pulsed\/intermittent\u003c\/p\u003e\n\u003cp\u003ePulse excitation current compatibility: DC to 0.01 second pulse width\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREQUENCY SOURCE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges: 1 to 2000 CPM, 0.01 to 999.99 Hz, 0.1 to 9999.9 Hz, 0.001 to 20.000 kHz\u003c\/p\u003e\n\u003cp\u003eAccuracy: +\/-(0.02% of reading + 0.01% of full scale)\u003c\/p\u003e\n\u003cp\u003eOutput waveform: square wave, zero crossing -1.0 to +5V peak-to-peak +\/-10%\u003c\/p\u003e\n\u003cp\u003eRisetime (10 to 90% of amplitude): \u0026lt; 10 microseconds\u003c\/p\u003e\n\u003cp\u003eOutput impedance: \u0026lt; 1 Ohm\u003c\/p\u003e\n\u003cp\u003eSource current: \u0026gt; 1 mA rms at 20 kHz\u003c\/p\u003e\n\u003cp\u003eShort circuit duration: infinite\u003c\/p\u003e\n\u003cp\u003eOptical coupling: green LED (HZ SYNC) flashes at output frequency\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFREQUENCY READ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRanges and accuracy: same as frequency source\u003c\/p\u003e\n\u003cp\u003eAccuracy: +\/-(0.02% of reading + 0.01% of full scale)Trigger level: 1 V rms, dc coupled\u003c\/p\u003e\n\u003cp\u003eInput impedance \u0026gt; 1 Meg Ohm + 60 pF\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOPERATING TEMPERATURE RANGE:\u003c\/strong\u003e -20 to 60C (-5 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTORAGE TEMPERATURE RANGE:\u003c\/strong\u003e -30 to 60C (-22 to 140F)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTEMPERATURE EFFECT:\u003c\/strong\u003e \u0026lt; +\/-0.005%\/C of full scale; cold junction sensor, \u0026lt; +\/-25 ppm\/C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRH RANGE:\u003c\/strong\u003e 10% \u0026lt;RH \u0026lt;90% (0 to 35C) non-condensing, 10% \u0026lt;RH \u0026lt;70% (0 to 60C) non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISOLATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVoltage: 60V rms between all milliamp functions\/read V DC \u0026amp; source V DC\/Thermocouple\/RTD\/Ohms\/Frequency\/Pressure\u003c\/p\u003e\n\u003cp\u003eCommon mode: 50\/60 Hz, 100 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNORMAL MODE REJECTION:\u003c\/strong\u003e 50\/60 Hz, 50 dB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOISE:\u003c\/strong\u003e \u0026lt; +\/- 1\/2 least significant digit from 0.1 to 10 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDIMENSIONS:\u003c\/strong\u003e 5.63 x 3.00 x 1.60 in (143 x 76 x 41 mm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWEIGHT:\u003c\/strong\u003e 12.1 oz (0.34 kg (including rubber boot \u0026amp; 4-AA batteries)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBATTERY LIFE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRead functions: \u0026gt; 20 hrs; read pressure \u0026gt; 7 hrs\u003c\/p\u003e\n\u003cp\u003eSource mA: 14 hrs @ 12 mA into 250 Ohms\u003c\/p\u003e\n\u003cp\u003ePwr\/meas mA: \u0026gt; 12 hrs at 30 mA\u003c\/p\u003e\n\u003cp\u003eSource V, Ohms, T\/C, pH, RTD, Hz: \u0026gt; 20 hrs\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLOW BATTERY:\u003c\/strong\u003e Indication with 1 hr of operation left\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePROTECTION AGAINST MISCONNECTION:\u003c\/strong\u003e Over-voltage protection to 60 vrms (rated for 30 seconds) Red LED indicates OVERLOAD or out of range conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDISPLAY:\u003c\/strong\u003e High contrast LCD with 0.35\" (9 mm) high digits on main \u0026amp; 0.2\" (5 mm) on mA display. LED backlight for use in dim lit areas\u003c\/p\u003e","brand":"PIE","offers":[{"title":"Default Title","offer_id":12627934707754,"sku":"CL-PI-830","price":4283.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/PIE_830_Displaying_RTD_and_Pwr_Xmtr_Rev_A.jpg?v=1535205378"},{"product_id":"ftk-simple-fixed-mount-blackbody-temperature-reference","title":"FTK Simple Fixed Mount Blackbody Temperature Reference\/Checker for Infrared Temperature Sensors","description":"\u003cul\u003e\n\u003cli\u003eQuick and Accurate Way to Check the Calibration of IR Pyrometers\u003c\/li\u003e\n\u003cli\u003eFixed Temperature from 35°C to 150°C - Depending on Model\u003c\/li\u003e\n\u003cli\u003eOutstanding Temperature Stability, Less than ±0.2°C Deviation\u003c\/li\u003e\n\u003cli\u003eLED Temperature Indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FTK provides a quick and accurate way to check the calibration of infrared temperature sensors. These rugged and portable units are designed to provide fast calibration checks anywhere they are needed, from the factory to the workshop or laboratory. Eighteen models are available; offering target temperatures from 35°C or 150°C, all providing outstanding stability with less than ±0.2°C deviation.\u003cbr\u003e\u003cbr\u003eThe FTK takes between 5 and 15 minutes to heat and stabilize at the desired temperature (depending on the model), and uses a clear LED to show when it has reached that temperature: Green when the FTK is warming up, Orange when the FTK is ready for operation and Red when the FTK is above the calibration temperature.\u003cbr\u003e\u003cbr\u003eThe FTK can be used with any infrared temperature sensor that is able to measure between 35°C and 150°C and can focus on a target area less than 50.8 mm diameter.\u003cbr\u003e\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page \u003cstrong\u003e\u003c\/strong\u003ethen  click on \u003cstrong\u003eADD TO CART \u003c\/strong\u003ebutton\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"177\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"113\"\u003e\u003cstrong\u003eTarget Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 35\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 45\u003c\/td\u003e\n\u003ctd\u003e45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 50\u003c\/td\u003e\n\u003ctd\u003e50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 55\u003c\/td\u003e\n\u003ctd\u003e55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 60\u003c\/td\u003e\n\u003ctd\u003e60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 65\u003c\/td\u003e\n\u003ctd\u003e65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 70\u003c\/td\u003e\n\u003ctd\u003e70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 75\u003c\/td\u003e\n\u003ctd\u003e75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 80\u003c\/td\u003e\n\u003ctd\u003e80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 85\u003c\/td\u003e\n\u003ctd\u003e85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 90\u003c\/td\u003e\n\u003ctd\u003e90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 95\u003c\/td\u003e\n\u003ctd\u003e95 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 100\u003c\/td\u003e\n\u003ctd\u003e100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 110\u003c\/td\u003e\n\u003ctd\u003e110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 120\u003c\/td\u003e\n\u003ctd\u003e120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 130\u003c\/td\u003e\n\u003ctd\u003e130 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 140\u003c\/td\u003e\n\u003ctd\u003e140 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR-CA- 150\u003c\/td\u003e\n\u003ctd\u003e150 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003cstrong\u003eDownloads\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/ftk-datasheet.pdf?v=1589900934\" title=\"FTK Blackbody reference data sheet.\" target=\"_blank\"\u003eFTK Data Sheet\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTarget Temperature:\u003c\/strong\u003e from 35 °C to 150 °C depending on model (see Ordering)\u003cbr\u003e\u003cstrong\u003eEmissivity:\u003c\/strong\u003e 0.98 ± 0.004 (for wavelength of 2 to 5.4 μm and 8 to 14 μm)\u003cbr\u003e\u003cstrong\u003eAperture Diameter:\u003c\/strong\u003e 50.8 mm\u003cbr\u003e\u003cstrong\u003eWarm-up Time:\u003c\/strong\u003e 5 minutes (FTK35) to 15 minutes (FTK150) max.\u003cbr\u003e\u003cstrong\u003eTemperature Uncertainty:\u003c\/strong\u003e 0.4 °C for ambient temp. 10 to 30 °C (FTK35 - 120)\u003cbr\u003e0.6 °C for ambient temp. 0 to 10 °C (FTK35 - 120)\u003cbr\u003e0.5 °C for ambient temp. 10 to 40 °C (FTK130 - 150)\u003cbr\u003e0.7 °C for ambient temp. 0 to 10 °C (FTK130 - 150)\u003cbr\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e 0.2°C\u003cbr\u003e\u003cstrong\u003eStability:\u003c\/strong\u003e 0.1°C\u003cbr\u003e\u003cstrong\u003eTemperature Uniformity:\u003c\/strong\u003e 0.2°C (central area ø 45 mm)\u003cbr\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e 0 to 70°C\u003cbr\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 10 to 85 %, non condensing\u003cbr\u003e\u003cstrong\u003eStatus:\u003c\/strong\u003e LED\u003cbr\u003e\u003cstrong\u003eGreen:\u003c\/strong\u003e warm-up\u003cbr\u003e\u003cstrong\u003eOrange:\u003c\/strong\u003e ready for operation\u003cbr\u003e\u003cstrong\u003eRed:\u003c\/strong\u003e above calibration temperature\u003cbr\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC, 1 A max.\u003cbr\u003e\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IP50 (EN 60529)\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.9 kg\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 64.5 x 81.0 x 133.5mm (diameter x D x H)\u003cbr\u003e\u003cstrong\u003eCE marking:\u003c\/strong\u003e according to EU regulations\u003cbr\u003e\u003cstrong\u003ePower Adapter: \u003c\/strong\u003e 100 to 240 V AC, 50 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/ftk-dimensions_81f5c1c9-2fb4-4fea-8900-346c456a95da_480x480.png?v=1589855411\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Calex","offers":[{"title":"IR-CA-FTK35  35°C Set Point","offer_id":32408595660880,"sku":"IR-CA-FTK35","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK45 45°C Set Point","offer_id":32408691474512,"sku":"IR-CA-FTK45","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK50  50°C Set Point","offer_id":32408699338832,"sku":"IR-CA-FTK50","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK55 55°C Set Point","offer_id":32408706711632,"sku":"IR-CA-FTK55","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK60  60°C Set Point","offer_id":32408752062544,"sku":"IR-CA-FTK60","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK65  65°C Set Point","offer_id":32408757993552,"sku":"IR-CA-FTK65","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK70 70°C Set Point","offer_id":32408764547152,"sku":"IR-CA-FTK70","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK75  75°C Set Point","offer_id":32408767299664,"sku":"IR-CA-FTK75","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK80  80°C Set Point","offer_id":32408773787728,"sku":"IR-CA-FTK80","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK85  85°C Set Point","offer_id":32408776769616,"sku":"IR-CA-FTK85","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK90  90°C Set Point","offer_id":32408780767312,"sku":"IR-CA-FTK90","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK100  100°C Set Point","offer_id":32408782930000,"sku":"IR-CA-FTK100","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK110 110°C Set Point","offer_id":32408790040656,"sku":"IR-CA-FTK110","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK120  120°C Set Point","offer_id":32408794726480,"sku":"IR-CA-FTK120","price":2585.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK130  130°C Set Point","offer_id":32408803311696,"sku":"IR-CA-FTK130","price":2655.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK140 140°C Set Point","offer_id":32408806490192,"sku":"IR-CA-FTK140","price":2655.0,"currency_code":"USD","in_stock":true},{"title":"IR-CA-FTK150 150°C Set Point","offer_id":32408815206480,"sku":"IR-CA-FTK150","price":2655.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/products\/ftk_l.jpg?v=1589855371"},{"product_id":"blackbody-calibrator-for-infrared-sensors-bx-500","title":"Blackbody Calibrator for Infrared Sensors, BX-500","description":"\u003cul\u003e\n\u003cli\u003eStable Blackbody Calibration Source for Infrared Sensors up to 500°C\u003c\/li\u003e\n\u003cli\u003eLarge 2.25 in (57 mm) Temperature-Controlled Target\u003c\/li\u003e\n\u003cli\u003eHigh Emissivity Target: 0.95\u003c\/li\u003e\n\u003cli\u003eAdjustable Temperature\u003c\/li\u003e\n\u003cli\u003eTemperature Range: 50°C to 500°C (122°F to 932°F)\u003c\/li\u003e\n\u003cli\u003eIncluded NIST Calibration Cert\u003c\/li\u003e\n\u003cli\u003e0.1°C\/°F Resolution with 0.1° Set-Point Increments\u003c\/li\u003e\n\u003cli\u003eAccuracy of ±0.5°C at 100°C and ±1.8°C at 500°C\u003c\/li\u003e\n\u003cli\u003eStability of ±0.1°C at 100°C and ±0.3°C at 500°C\u003c\/li\u003e\n\u003cli\u003eContact Calibration Well Located Behind the Blackbody Surface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BX-500 Blackbody Calibrator provides a stable, high-performance calibration standard for verifying the accuracy of non-contact infrared temperature sensors, including in-line infrared pyrometers and handheld IR thermometers.\u003c\/p\u003e\n\u003cp\u003eDesigned for calibrations up to 500°C, the BX-500 features a large 2.25 inch (57 mm) temperature-controlled blackbody target with an emissivity of 0.95. The isothermal target can be controlled in set-point increments of 0.1° across a temperature range of 50°C to 500°C.\u003c\/p\u003e\n\u003cp\u003eThe BX-500 offers dependable calibration performance with accuracy of ±0.5°C at 100°C and ±1.8°C at 500°C. Temperature stability is ±0.1°C at 100°C and ±0.3°C at 500°C, making it well suited for routine verification of infrared temperature measurement devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarge Blackbody Target\u003c\/strong\u003e\u003cbr\u003eThe 2.25 inch target provides a practical calibration surface for a variety of infrared sensors and thermometers. Its 0.95 emissivity helps provide a consistent reference target for non-contact temperature calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigher Precision Calibration Option\u003c\/strong\u003e\u003cbr\u003eFor applications requiring even higher precision, a contact calibration well is located directly behind the blackbody surface. When used with an optional digital RTD thermometer and calibrated secondary probe, accuracies of ±0.1°C can be achieved.\u003c\/p\u003e\n\u003cp\u003eThe BX-500 includes an AC power cable and is available for 230 VAC or 110 VAC power requirements. Heating time is approximately 40 minutes to maximum temperature, and cooling time is approximately 45 minutes from maximum temperature to 100°C.\u003c\/p\u003e\n\u003cp\u003e[to_order_table]\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e the model below scroll to the top of the page \u003cstrong\u003e\u003c\/strong\u003ethen  click on \u003cstrong\u003eADD TO CART \u003c\/strong\u003ebutton\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"height: 98px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.6px;\"\u003e\n\u003ctd style=\"width: 38.093%; height: 19.6px;\"\u003e \u003cstrong\u003ePART NUMBERS\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 61.6158%; height: 19.6px;\"\u003e\u003cstrong\u003eDESCRIPTION\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"width: 38.093%; height: 39.2px;\"\u003eBX-500\u003c\/td\u003e\n\u003ctd style=\"width: 61.6158%; height: 39.2px;\"\u003eBlackbody Calibrator for Infrared Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[to_order_table]\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 50°C to 500°C (122°F to 932°F)\u003cbr\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.5°C at 100°C (±1.0°F at 212°F); ±1.8°C at 500°C (±3.6°F at 932°F)\u003cbr\u003e\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.1°C at 100°C (±0.2°F at 212°F); ±0.3°C at 500°C (±0.6°F at 932°F)\u003cbr\u003e\u003cstrong\u003eTarget Size:\u003c\/strong\u003e 2.25 in (57 mm)\u003cbr\u003e\u003cstrong\u003eTarget Emissivity:\u003c\/strong\u003e 0.95\u003cbr\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1°C\/°F\u003cbr\u003e\u003cstrong\u003eHeating Time:\u003c\/strong\u003e 40 minutes to maximum temperature\u003cbr\u003e\u003cstrong\u003eCooling Time:\u003c\/strong\u003e 45 minutes from maximum temperature to 100°C\u003cbr\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 230 VAC (±10%), 1.5 A; or 110 VAC, 3 A\u003cbr\u003e\u003cstrong\u003eSize (HxWxD):\u003c\/strong\u003e 180 mm x 114 mm x 233 mm\u003cbr\u003e\u003cstrong\u003eWeight: \u003c\/strong\u003e6lbs\u003cbr\u003e\u003cstrong\u003eAccessories Included:\u003c\/strong\u003e AC power cable \u003cbr\u003e\u003cstrong\u003eCalibration Cert Included\u003c\/strong\u003e\u003c\/p\u003e","brand":"IOThrifty","offers":[{"title":"Default Title","offer_id":50124855247085,"sku":"BX-500","price":1460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/224cf9d3c48b6990fbc96b4cb63bd65d.png?v=1781872195"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/collections\/d5f7da54e54a5091ee55d5307a7d6987.jpg?v=1672495623","url":"https:\/\/www.iothrifty.com\/collections\/calibrators.oembed?page=2","provider":"IOThrifty","version":"1.0","type":"link"}