{"product_id":"multi-channel-oven-profiling-system","title":"Multi-channel Oven Profiling System","description":"\u003cul\u003e\n\u003cli\u003e4 or 8-Channel Thermocouple Temperature Data Logger with Thermal Shield\u003c\/li\u003e\n\u003cli\u003eWithstands Oven Temperatures up to 350°C (662°F) for up to 25 Minutes When Properly Sealed\u003c\/li\u003e\n\u003cli\u003eIdeal for Oven Profiling, Powder Coating Cure Ovens, Wet Coating Cure Ovens, Batch Ovens and Conveyor Ovens\u003c\/li\u003e\n\u003cli\u003eExternal Thermocouple Probes Provide Accurate Measurements with Fast Response Times\u003c\/li\u003e\n\u003cli\u003eSupports Thermocouple Types J, K, T, E, R, S, B and N\u003c\/li\u003e\n\u003cli\u003eProgrammable Start Time with Push Button, Immediate or Delayed Start Options\u003c\/li\u003e\n\u003cli\u003eReusable, Battery Powered and Compact Stainless Steel Enclosure\u003c\/li\u003e\n\u003cli\u003eUSB Interface with User-Friendly MadgeTech Software for Graphing, Statistics and Excel Export\u003c\/li\u003e\n\u003cli\u003eSystem Includes:\u003cbr\u003eTCTempX Thermocouple-Based Temperature Data Logger\u003cbr\u003eThermal Insulated Enclosure\u003cbr\u003eType K Thermocouples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe ThermoVaultX Series is a thermally insulated, battery powered oven temperature data logger designed for temperature profiling in high heat industrial processes. Available in 4-channel and 8-channel versions, it combines a TCTempX data logger with a protective thermal enclosure to record thermocouple temperature data inside ovens and other extreme temperature environments.\u003c\/p\u003e\n\u003cp\u003eThe ThermoVaultX is well suited for validating and optimizing powder coating cure ovens, wet coating cure ovens, batch ovens and conveyor ovens. Oven profiling helps users confirm process control, identify process issues and produce consistent product quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Thermal Protection\u003c\/strong\u003e\u003cbr\u003eThe stainless steel thermal enclosure acts as a buffer to protect the logger during exposure to elevated temperatures. When properly sealed and used according to the specified exposure limits, the ThermoVaultX system can withstand ambient temperatures up to 350°C (662°F) for up to 25 minutes. Maximum exposure duration varies by oven temperature, with longer allowable times at lower temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Channel Thermocouple Recording\u003c\/strong\u003e\u003cbr\u003eThe ThermoVaultX Series is available with either 4 or 8 thermocouple channels, allowing multiple points in an oven or process to be monitored during a single run. The logger supports J, K, T, E, R, S, B and N thermocouple types with automatic thermocouple linearization and automatic cold junction compensation based on the internal channel. Type K thermocouples are included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware and Data Analysis\u003c\/strong\u003e\u003cbr\u003eMadgeTech software allows recorded data to be downloaded to a computer and viewed in degrees Celsius, degrees Fahrenheit, Kelvin or Rankine. Data can be displayed in graph or tabular form, zoomed for closer inspection and exported to Excel for additional analysis. Software features include multiple graph overlay, statistics, min\/max\/average lines, digital calibration, summary view and calculations such as Mean Kinetic Temperature.\u003c\/p\u003e\n\u003cp\u003eThe ThermoVaultX offers programmable start options including push button start, immediate software start and delayed start up to six months in advance. Readings are date and time stamped, and the logger provides 524,032 readings per channel on the 4-channel model or 262,016 readings per channel on the 8-channel model with all channels enabled.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eDisclaimer \u0026amp; Terms of Use\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003eListed specifications can be used to determine maximum allowable exposure times for the TCTempX with ThermoVaultX. The barrier extends the operating temperature of the logger up to 350 °C (662 °F). Both the data logger and ThermoVaultX must be at ambient temperature, approximately 25°C (77°F) before being placed in the extreme temperature environment. Immediately following exposure to high temperature, the data logger should be removed from the ThermoVaultX, using appropriate precautions, as it could be VERY hot. Failing to remove the data logger may allow heat trapped in the ThermoVaultX to continue to heat the data logger to potentially unsafe levels. The ThermoVaultX may take hours to fully cool down. Even if the exterior of the ThermoVaultX is cool to the touch, the interior of the barrier and its contents may still be VERY hot. Allow the entire system to cool down to approximatel 25 °C (77 °F) before successive cycle.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInternal Channels\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20 °C to +60 °C (-4 °F to +140 °F)\u003cbr\u003e\u003cstrong\u003eTemperature Resolution:\u003c\/strong\u003e 0.01 °C (0.018 °F)\u003cbr\u003e\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e ±0.5 °C (0 °C to 50 °C)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eRemote Channels\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRemote Channel Thermocouple Types:\u003c\/strong\u003e J, K, T, E, R, S, B, N\u003cbr\u003e\u003cstrong\u003eThermocouple Connection:\u003c\/strong\u003e Female subminiature (SMP)\u003cbr\u003e\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e Automatic, based on internal channel\u003cbr\u003e\u003cstrong\u003eJ Thermocouple Range:\u003c\/strong\u003e -210 to +760 °C, 0.1 °C resolution, ±0.5 °C accuracy\u003cbr\u003e\u003cstrong\u003eK Thermocouple Range:\u003c\/strong\u003e -270 to +1370 °C, 0.1 °C resolution, ±0.5 °C accuracy\u003cbr\u003e\u003cstrong\u003eT Thermocouple Range:\u003c\/strong\u003e -270 to +400 °C, 0.1 °C resolution, ±0.5 °C accuracy\u003cbr\u003e\u003cstrong\u003eE Thermocouple Range:\u003c\/strong\u003e -270 to +980 °C, 0.1 °C resolution, ±0.5 °C accuracy\u003cbr\u003e\u003cstrong\u003eR Thermocouple Range:\u003c\/strong\u003e -50 to +1760 °C, 0.5 °C resolution, ±2.0 °C accuracy\u003cbr\u003e\u003cstrong\u003eS Thermocouple Range:\u003c\/strong\u003e -50 to +1760 °C, 0.5 °C resolution, ±2.0 °C accuracy\u003cbr\u003e\u003cstrong\u003eB Thermocouple Range:\u003c\/strong\u003e +50 to +1820 °C, 0.5 °C resolution, ±2.0 °C accuracy\u003cbr\u003e\u003cstrong\u003eN Thermocouple Range:\u003c\/strong\u003e -270 to +1300 °C, 0.1 °C resolution, ±0.5 °C accuracy\u003cbr\u003e\u003cstrong\u003eThermocouple Accuracy Note:\u003c\/strong\u003e Thermocouple accuracy specified with 24 AWG diameter thermocouple wires.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Exposure Time\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e100 °C (212 °F):\u003c\/strong\u003e 110 minutes\u003cbr\u003e\u003cstrong\u003e150 °C (302 °F):\u003c\/strong\u003e 62 minutes\u003cbr\u003e\u003cstrong\u003e200 °C (392 °F):\u003c\/strong\u003e 45 minutes\u003cbr\u003e\u003cstrong\u003e250 °C (482 °F):\u003c\/strong\u003e 35 minutes\u003cbr\u003e\u003cstrong\u003e260 °C (500 °F):\u003c\/strong\u003e 33 minutes\u003cbr\u003e\u003cstrong\u003e300 °C (572 °F):\u003c\/strong\u003e 30 minutes\u003cbr\u003e\u003cstrong\u003e350 °C (662 °F):\u003c\/strong\u003e 25 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStart Modes:\u003c\/strong\u003e Push button start and software programmable immediate start or delay start up to six months in advance\u003cbr\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e 4-channel: 524,032 readings per channel; 8-channel: 262,016 readings per channel\u003cbr\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e 1 per channel and 2 status LEDs\u003cbr\u003e\u003cstrong\u003eReading Rate:\u003c\/strong\u003e 4 Hz up to 1 reading every 24 hours\u003cbr\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e Digital calibration through software\u003cbr\u003e\u003cstrong\u003eCalibration Date:\u003c\/strong\u003e Automatically recorded within device\u003cbr\u003e\u003cstrong\u003eBattery Type:\u003c\/strong\u003e 9 V lithium battery included, user replaceable\u003cbr\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 18 months typical\u003cbr\u003e\u003cstrong\u003eData Format:\u003c\/strong\u003e Date and time stamped °C, °F, K, °R, mV, V\u003cbr\u003e\u003cstrong\u003eTime Accuracy:\u003c\/strong\u003e ±1 minute\/month\u003cbr\u003e\u003cstrong\u003eComputer Interface:\u003c\/strong\u003e USB-A to micro USB cable included; 460,800 baud\u003cbr\u003e\u003cstrong\u003eOperating System Compatibility:\u003c\/strong\u003e Windows XP SP3 or later\u003cbr\u003e\u003cstrong\u003eSoftware Compatibility:\u003c\/strong\u003e Standard Software version 4.2.17.0 or later; Secure Software version 4.2.16.0 or later\u003cbr\u003e\u003cstrong\u003eInternal TCTempX Environment:\u003c\/strong\u003e -20 °C to +60 °C, 0 %RH to 95 %RH non-condensing\u003cbr\u003e\u003cstrong\u003eThermoVaultX System Environment:\u003c\/strong\u003e -20 °C to +350 °C, 0 %RH to 95 %RH non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDimensions with Handles, Brackets and Front Enclosure Latches:\u003c\/strong\u003e 12.3 in x 6.65 in x 2.45 in (312 mm x 168 mm x 62 mm)\u003cbr\u003e\u003cstrong\u003eEnclosure Case Only Dimensions:\u003c\/strong\u003e 9.1 in x 5.9 in x 2.45 in (231 mm x 149 mm x 62 mm)\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 4-channel: 8.85 lb (4.01 kg); 8-channel: 8.98 lb (4.07 kg)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eThermoVaultX4 PN 901350-00:\u003c\/strong\u003e Thermal Shield with a 4-channel temperature data logger, 72 inch 24 AWG type K thermocouples (0 °C to +482 °C), USB-A to micro USB cable and universal power adapter\u003cbr\u003e\u003cstrong\u003eThermoVaultX8 PN 900437-00:\u003c\/strong\u003e Thermal Shield with an 8-channel temperature data logger, 72 inch 24 AWG type K thermocouples (0 °C to +482 °C), USB-A to micro USB cable and universal power adapter\u003cbr\u003e\u003cstrong\u003eU9VL-J PN 901804-00:\u003c\/strong\u003e Replacement battery for TCTempX Series\u003c\/p\u003e","brand":"IOThrifty","offers":[{"title":"Four Temperature Channels","offer_id":50020636623085,"sku":"ThermoVaultX4","price":1704.0,"currency_code":"USD","in_stock":true},{"title":"Eight Temperature Channels","offer_id":50020636655853,"sku":"ThermoVaultX8","price":1924.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/48cc708fb226307ccc2e401de508e833.png?v=1779912834","url":"https:\/\/www.iothrifty.com\/products\/multi-channel-oven-profiling-system","provider":"IOThrifty","version":"1.0","type":"link"}