{"product_id":"n1500-lc-load-cell-panel-meter","title":"N1500-LC - Load Cell Panel Meter","description":"\u003cul\u003e\n\u003cli\u003eDigital Panel Meter Designed for Weighing Systems with Load Cells\u003c\/li\u003e\n\u003cli\u003eAccepts 4-20 mA, 0-20 mA, 0-50 mV, 0-20 mV, and -20 to 20 mV Inputs\u003c\/li\u003e\n\u003cli\u003e6-Digit LED Display for Process Value and Parameter Indication\u003c\/li\u003e\n\u003cli\u003e5 Vdc or 10 Vdc Load Cell Excitation Supply\u003c\/li\u003e\n\u003cli\u003eHold, Peak Hold, Tare, Zero Tare, and Automatic Zero Functions\u003c\/li\u003e\n\u003cli\u003eMemory for Maximum and Minimum Values\u003c\/li\u003e\n\u003cli\u003eTwo Alarm Outputs Standard with Optional 3rd and 4th Alarm Relays\u003c\/li\u003e\n\u003cli\u003eOptional 0-20 mA or 4-20 mA Process Variable Retransmission\u003c\/li\u003e\n\u003cli\u003eOptional RS485 Modbus RTU Serial Communication\u003c\/li\u003e\n\u003cli\u003eFront Panel Configuration with No Circuit Changes Required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NOVUS N1500LC is a digital panel meter designed specifically for weighing systems using load cells. It provides a clear 6-digit LED display for measured values and programming parameters, making it well suited for industrial weighing, monitoring, and panel-mounted measurement applications.\u003c\/p\u003e\n\u003cp\u003eThe N1500LC supports a wide range of electrical input signals, including 4-20 mA, 0-20 mA, 0-50 mV, 0-20 mV, and -20 to 20 mV. Its configurable indication range allows the display to be set up for the application, while the built-in 5 Vdc or 10 Vdc auxiliary supply provides excitation power for compatible load cells.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeighing and Load Cell Functions\u003c\/strong\u003e\u003cbr\u003eThe N1500LC includes functions commonly needed in scale and weighing applications, such as Tare, Zero Tare, Automatic Zero, Hold, and Peak Hold. It can also store maximum and minimum measured values, helping operators monitor process limits or capture peak weighing events.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarms and Output Options\u003c\/strong\u003e\u003cbr\u003eThe standard unit includes two alarm outputs, with optional configurations available for up to four alarm relays. Alarm functions include low alarm, high alarm, open sensor detection, and differential alarm modes. Optional process variable retransmission is available as a 0-20 mA or 4-20 mA analog output for sending the measured value to other control or monitoring equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication and Configuration\u003c\/strong\u003e\u003cbr\u003eOptional RS485 Modbus RTU communication allows the N1500LC to be integrated into industrial networks for remote monitoring and data acquisition. Configuration is performed through the front keypad, allowing input type, alarm behavior, display scaling, digital input functions, and other parameters to be programmed without changing the internal circuit.\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e Downloads\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/Manual_N1500LC_EN_1__edited.pdf?v=1794249016\" target=\"_blank\" title=\"N1500-LC Manual\" rel=\"noopener\"\u003eN1500-LC Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/N1500_Communication_Manual_EN.pdf?v=1794249015\" target=\"_blank\" title=\"N1500-LC Communication Interface Guide\" rel=\"noopener\"\u003eCommuncation Interface Guide\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[show_stocked_pn]\u003c\/p\u003e\n\u003cp\u003e[to_order_table]\u003c\/p\u003e\n\u003ctable style=\"background-color: #c0ecfb;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cem\u003e \u003cstrong\u003eTo Order\u003c\/strong\u003e click on the model no.(or scroll to the top of page and select your configuration) then click the \u003cstrong\u003eADD TO CART \u003c\/strong\u003ebutton\u003c\/em\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px; width: 27%;\"\u003e\u003cstrong\u003eModel No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 22px; width: 63%;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3333px;\"\u003e\n\u003ctd style=\"height: 34.3333px; width: 27%;\"\u003e\u003ca href=\"https:\/\/www.iothrifty.com\/products\/n1500-lc-load-cell-panel-meter?variant=68244922368237\" title=\"N1500-LC-2R\"\u003eN1500-LC-2R\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 34.3333px; width: 63%;\"\u003e2 Relays + 4-20 mA Retransmission, 100-240 Vac\/dc Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3333px;\"\u003e\n\u003ctd style=\"height: 34.3333px; width: 27%;\"\u003e\u003ca href=\"https:\/\/www.iothrifty.com\/products\/n1500-lc-load-cell-panel-meter?variant=68244922401005\" title=\"N1500-LC-4R-RS485\"\u003eN1500-LC-4R-RS485\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 34.3333px; width: 63%;\"\u003e4 Relays + 4-20 mA Retransmission + RS485, 100-240 Vac\/dc Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3333px;\"\u003e\n\u003ctd style=\"height: 34.3333px; width: 27%;\"\u003e\u003ca href=\"https:\/\/www.iothrifty.com\/products\/n1500-lc-load-cell-panel-meter?variant=68244922433773\" title=\"N1500-LC-4R-RS485-24V\"\u003eN1500-LC-4R-RS485-24V\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 34.3333px; width: 63%;\"\u003e4 Relays + 4-20 mA Retransmission + RS485, 24 Vdc Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[to_order_table]\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 48 x 96 x 92 mm (1\/8 DIN)\u003cbr\u003e\u003cstrong\u003eApproximate Weight:\u003c\/strong\u003e 250 g\u003cbr\u003e\u003cstrong\u003ePanel Cut-out:\u003c\/strong\u003e 45 x 93 mm (+0.5 -0.0 mm)\u003cbr\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 100 to 240 Vac\/dc (±10 %), 50\/60 Hz\u003cbr\u003e\u003cstrong\u003eOptional 24 V Power:\u003c\/strong\u003e 12 to 24 Vcc \/ 24 Vca (-10 % \/ +20%)\u003cbr\u003e\u003cstrong\u003eMaximum Consumption:\u003c\/strong\u003e 7.5 VA\u003cbr\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 5 to 50 °C\u003cbr\u003e\u003cstrong\u003eMaximum Relative Humidity:\u003c\/strong\u003e 80 % up to 30 °C. For temperatures above 30 °C, decrease 3 % per °C.\u003cbr\u003e\u003cstrong\u003eUse:\u003c\/strong\u003e Indoor use; Installation category II, pollution degree 2; altitude \u0026lt; 2000 m\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eInput Types\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0-20 mA, 4-20 mA\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 0-50 mV, 0-20 mV, -20 to 20 mV\u003cbr\u003e\u003cstrong\u003eNon-linear Inputs:\u003c\/strong\u003e c.4-20, c.0-20, c.50, c.-20, c.20 with customized linearization\u003cbr\u003e\u003cstrong\u003eProgrammable Indication Range:\u003c\/strong\u003e -31000 to 31000, 0 to 60000, or 0 to 120000 with only even values\u003cbr\u003e\u003cstrong\u003eInternal Resolution:\u003c\/strong\u003e 128000 levels\u003cbr\u003e\u003cstrong\u003eDisplay Resolution:\u003c\/strong\u003e 62000 levels\u003cbr\u003e\u003cstrong\u003eInput Sample Rate:\u003c\/strong\u003e 15 samples per second\u003cbr\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e 0.2 % of span\u003cbr\u003e\u003cstrong\u003eInput Impedance 0-50 mV:\u003c\/strong\u003e \u0026gt;10 MΩ\u003cbr\u003e\u003cstrong\u003eInput Impedance 0-20 mA \/ 4-20 mA:\u003c\/strong\u003e 15 Ω (+2 Vdc @ 20 mA)\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eAnalog Output:\u003c\/strong\u003e 0-20 mA or 4-20 mA, 550 Ω max.\u003cbr\u003e\u003cstrong\u003eAnalog Output Resolution:\u003c\/strong\u003e 4000 levels, isolated, for control or retransmission of PV and SP\u003cbr\u003e\u003cstrong\u003eRelay Output ALM1 and ALM2:\u003c\/strong\u003e SPDT: 3 A \/ 240 Vac (3 A \/ 30 Vdc Res.)\u003cbr\u003e\u003cstrong\u003eRelay Output ALM3 and ALM4:\u003c\/strong\u003e SPST-NO: 1.5 A \/ 250 Vac (3 A \/ 30 Vdc Res.)\u003cbr\u003e\u003cstrong\u003eAuxiliary Voltage Supply:\u003c\/strong\u003e 5 or 10 Vdc, ±1 %, 35 mA\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eSerial Communication:\u003c\/strong\u003e Optional RS485 Modbus RTU\u003cbr\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e 2-wire RS485 connection with a master and up to 31 digital panel meters, addressable up to 247\u003cbr\u003e\u003cstrong\u003eMaximum Connection Distance:\u003c\/strong\u003e 1000 meters\u003cbr\u003e\u003cstrong\u003eBaud Rate:\u003c\/strong\u003e 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115600 bps\u003cbr\u003e\u003cstrong\u003eData Bits:\u003c\/strong\u003e 8 with no parity or even parity\u003cbr\u003e\u003cstrong\u003eStop Bits:\u003c\/strong\u003e 1\u003cbr\u003e\u003cstrong\u003eResponse Start Time:\u003c\/strong\u003e Maximum 100 ms after receiving the command\u003cbr\u003e\u003cstrong\u003eProtocol:\u003c\/strong\u003e MODBUS RTU\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eFront Panel:\u003c\/strong\u003e IP65, polycarbonate UL94 V-2\u003cbr\u003e\u003cstrong\u003eHousing:\u003c\/strong\u003e IP20, ABS + PC UL94 V-0\u003cbr\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e Suitable for terminal type fork 6.3 mm\u003cbr\u003e\u003cstrong\u003eStarts Operation:\u003c\/strong\u003e 3 seconds after power-up\u003cbr\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e EN61326-1:1997 and EN61326-1\/A1:1998\u003cbr\u003e\u003cstrong\u003eSafety:\u003c\/strong\u003e EN61010-1:1993 and EN61010-1\/A2:1995\u003c\/p\u003e","brand":"IOThrifty","offers":[{"title":"2 relays + 4-20 mA Retransmission - 100-240 Vac\/dc","offer_id":68244922368237,"sku":"N1500-LC-2R","price":278.0,"currency_code":"USD","in_stock":true},{"title":"4 relays +  4-20 mA Retransmission + RS485 - 100-240 Vac\/dc","offer_id":68244922401005,"sku":"N1500-LC-4R-RS485","price":351.0,"currency_code":"USD","in_stock":true},{"title":"4 relays +  4-20 mA Retransmission + RS485 - 24 Vdc","offer_id":68244922433773,"sku":"N1500-LC-4R-RS485-24V","price":353.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/b7ed952210282fa56cabaa2261a80573.png?v=1794245433","url":"https:\/\/www.iothrifty.com\/products\/n1500-lc-load-cell-panel-meter","provider":"IOThrifty","version":"1.0","type":"link"}