{"product_id":"voltx-4-8-12-and-16-channel-dc-voltage-data-logger","title":"VoltX - 4, 8, 12, and 16 channel DC Voltage Data Logger","description":"\u003cul\u003e\n\u003cli\u003e4, 8, 12 and 16-Channel DC Voltage Data Loggers\u003c\/li\u003e\n\u003cli\u003eAvailable Voltage Ranges: ±160 mV, ±3.2 V or -8 V to +32 V\u003c\/li\u003e\n\u003cli\u003eUp to 4 Hz Reading Rate with Simultaneous Multi-Channel Logging\u003c\/li\u003e\n\u003cli\u003e18 Month Typical Battery Life with User Replaceable 9 V Lithium Battery\u003c\/li\u003e\n\u003cli\u003eUSB-A to Micro USB Connection for Setup and Data Download\u003c\/li\u003e\n\u003cli\u003eProgrammable Engineering Units for Scaling Voltage Signals\u003c\/li\u003e\n\u003cli\u003eReal-Time Operation with PC Monitoring and Recording\u003c\/li\u003e\n\u003cli\u003eEnable or Disable Channels to Maximize Memory Capacity\u003c\/li\u003e\n\u003cli\u003eChannel Naming with Up to 10 Characters per Channel\u003c\/li\u003e\n\u003cli\u003eCalibration Certificate Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe VoltX Series is a family of multi-channel, battery powered DC voltage data loggers designed for monitoring voltage signals across 4, 8, 12 or 16 channels. With available input ranges of ±160 mV, ±3.2 V and -8 V to +32 V, the VoltX Series is well suited for low level signal monitoring, battery studies, power supply monitoring, process plants, environmental studies and research and development applications.\u003c\/p\u003e\n\u003cp\u003eEach VoltX data logger supports a reading rate of up to 4 Hz and logs data from all channels simultaneously. The devices use non-volatile solid state memory for data security, even if the battery becomes discharged. Users can enable or disable individual channels to maximize memory capacity, and each channel can be assigned a custom name for easier identification in reports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Voltage Monitoring\u003c\/strong\u003e\u003cbr\u003eThe VoltX Series is available in multiple channel counts and voltage ranges to match a wide variety of monitoring requirements. The ±160 mV models use differential wiring with three-position removable screw terminals, while the ±3.2 V and -8 V to +32 V models use single-ended wiring with two-position removable screw terminals. Programmable engineering units allow native voltage readings to be scaled for use with sensors that output voltage signals, such as temperature, CO2, flow rate and other measurement devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimple Setup and Data Analysis\u003c\/strong\u003e\u003cbr\u003eUsing MadgeTech software, the VoltX Series can be started, stopped and downloaded quickly through a standard USB-A to Micro USB connection. Data can be viewed in graphical, tabular and statistical formats, with features such as multiple graph overlay, zoom, statistics, min\/max\/average lines and automatic export to Excel for additional analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Field Deployment\u003c\/strong\u003e\u003cbr\u003eThe VoltX Series is designed for minimal long-term maintenance, with an 18 month typical battery life and a user replaceable 9 V lithium battery. Start modes include immediate start, delayed start up to six months in advance, pushbutton manual start and real-time recording while connected to a PC. A universal power adapter and USB-A to Micro USB cable are included.\u003c\/p\u003e\n\u003ctable style=\"height: 58.7856px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5952px;\"\u003e\n\u003ctd style=\"height: 19.5952px;\"\u003e \u003cstrong\u003eDownloads\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5952px;\"\u003e\n\u003ctd style=\"height: 19.5952px;\"\u003e\u003ca title=\"VoltX Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/DOC-1381009-00_2.pdf?v=1780064514\"\u003eVoltX Datasheet\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5952px;\"\u003e\n\u003ctd style=\"height: 19.5952px;\"\u003e\u003ca title=\"VoltX User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/DOC1381036-00_1.pdf?v=1780064403\"\u003eVoltX User Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e 4, 8, 12 and 16-Channel DC Voltage Data Logger\u003cbr\u003e\u003cstrong\u003eInput Connection:\u003c\/strong\u003e Removable screw terminals\u003cbr\u003e\u003cstrong\u003eAvailable Models:\u003c\/strong\u003e ±160 mV, ±3.2 V and -8 V to +32 V\u003cbr\u003e\u003cstrong\u003eReading Rate:\u003c\/strong\u003e 4 Hz up to 1 reading every 24 hours\u003cbr\u003e\u003cstrong\u003eAnalog Conversion Time:\u003c\/strong\u003e 150 ms\u003cbr\u003e\u003cstrong\u003eFrequency Rejection:\u003c\/strong\u003e 60 + 50 Hz\u003cbr\u003e\u003cstrong\u003eTemperature Coefficient:\u003c\/strong\u003e 25 ppm\/°C\u003cbr\u003e\u003cstrong\u003eSpecified Accuracy Range:\u003c\/strong\u003e Nominal range @ 25 ºC\u003cbr\u003e\u003cstrong\u003eEngineering Units:\u003c\/strong\u003e Native measurement units can be scaled to display measurement units of another type\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e±160 mV Model\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e ±160 mV\u003cbr\u003e\u003cstrong\u003eVoltage Resolution:\u003c\/strong\u003e 0.02 μV\u003cbr\u003e\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e ±0.032 mV\u003cbr\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 1 MΩ\u003cbr\u003e\u003cstrong\u003eMaximum Voltage Between Inputs and Ground:\u003c\/strong\u003e +3 V\u003cbr\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Differential wiring, three-position removable screw terminal connections\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e±3.2 V Model\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e ±3.2 V\u003cbr\u003e\u003cstrong\u003eVoltage Resolution:\u003c\/strong\u003e 0.0004 mV\u003cbr\u003e\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e ±0.0032 V\u003cbr\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 125 kΩ\u003cbr\u003e\u003cstrong\u003eMaximum Voltage Between Inputs and Ground:\u003c\/strong\u003e +50 V\u003cbr\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Single ended wiring, two-position removable screw terminal connections\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003e-8 V to +32 V Model\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e -8 V to +32 V\u003cbr\u003e\u003cstrong\u003eVoltage Resolution:\u003c\/strong\u003e 0.004 mV\u003cbr\u003e\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e ±0.02 V\u003cbr\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 125 kΩ\u003cbr\u003e\u003cstrong\u003eMaximum Voltage Between Inputs and Ground:\u003c\/strong\u003e +50 V\u003cbr\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Single ended wiring, two-position removable screw terminal connections\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eStart Modes:\u003c\/strong\u003e Software programmable immediate start or delay start up to six months in advance\u003cbr\u003e\u003cstrong\u003eReal Time Recording:\u003c\/strong\u003e May be used with PC to monitor and record data in real time\u003cbr\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e 4-channel: 698,709 readings; 8-channel: 349,354 readings; 12-channel: 232,903 readings; 16-channel: 174,677 readings\u003cbr\u003e\u003cstrong\u003eLEDs:\u003c\/strong\u003e 1 per channel and 2 status LEDs\u003cbr\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e Digital calibration through software\u003cbr\u003e\u003cstrong\u003eCalibration Date:\u003c\/strong\u003e Automatically recorded within device\u003cbr\u003e\u003cstrong\u003eBattery Type:\u003c\/strong\u003e 9 V lithium battery included, user replaceable\u003cbr\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e 18 months typical\u003cbr\u003e\u003cstrong\u003eData Format:\u003c\/strong\u003e Date and time stamped V, mV, μV and engineering units specified through software\u003cbr\u003e\u003cstrong\u003eTime Accuracy:\u003c\/strong\u003e ±1 minute\/month\u003cbr\u003e\u003cstrong\u003eComputer Interface:\u003c\/strong\u003e USB-A to micro USB cable included; 460,800 baud\u003cbr\u003e\u003cstrong\u003eOperating System Compatibility:\u003c\/strong\u003e Windows XP SP3 or later\u003cbr\u003e\u003cstrong\u003eSoftware Compatibility:\u003c\/strong\u003e Standard Software version 4.2.19.0 or later; Secure Software version 4.2.18.0 or later\u003cbr\u003e\u003cstrong\u003eOperating Environment:\u003c\/strong\u003e -20 ºC to +60 ºC (-4 ºF to +140 ºF), 0 %RH to 95 %RH non-condensing\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e4-Channel:\u003c\/strong\u003e 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm)\u003cbr\u003e\u003cstrong\u003e8-Channel:\u003c\/strong\u003e 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm)\u003cbr\u003e\u003cstrong\u003e12-Channel:\u003c\/strong\u003e 2.70 in x 7.25 in x 1.68 in (65.6 mm x 184.2 mm x 42.7 mm)\u003cbr\u003e\u003cstrong\u003e16-Channel:\u003c\/strong\u003e 2.70 in x 7.25 in x 2.14 in (65.6 mm x 184.2 mm x 54.4 mm)\u003cbr\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Black anodized aluminum\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 4-channel: 13 oz (368 g); 8-channel: 13 oz (368 g); 12-channel: 20 oz (580 g); 16-channel: 28 oz (800 g)\u003cbr\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE\u003c\/p\u003e","brand":"Madgetech","offers":[{"title":"4 Channel \/ 160mV","offer_id":50036334035181,"sku":"VOLTX-4-160MV","price":714.0,"currency_code":"USD","in_stock":true},{"title":"4 Channel \/ 3.2V","offer_id":50036334067949,"sku":"VOLTX-4-3V","price":714.0,"currency_code":"USD","in_stock":true},{"title":"4 Channel \/ 32V","offer_id":50036334100717,"sku":"VOLTX-4-32V","price":714.0,"currency_code":"USD","in_stock":true},{"title":"8 Channel \/ 160mV","offer_id":50036334133485,"sku":"VOLTX-8-160MV","price":1154.0,"currency_code":"USD","in_stock":true},{"title":"8 Channel \/ 3.2V","offer_id":50036334166253,"sku":"VOLTX-8-3V","price":1154.0,"currency_code":"USD","in_stock":true},{"title":"8 Channel \/ 32V","offer_id":50036334199021,"sku":"VOLTX-8-32V","price":1154.0,"currency_code":"USD","in_stock":true},{"title":"12 Channel \/ 160mV","offer_id":50036334231789,"sku":"VOLTX-12-160MV","price":1429.0,"currency_code":"USD","in_stock":true},{"title":"12 Channel \/ 3.2V","offer_id":50036334264557,"sku":"VOLTX-12-3V","price":1429.0,"currency_code":"USD","in_stock":true},{"title":"12 Channel \/ 32V","offer_id":50036334297325,"sku":"VOLTX-12-32V","price":1429.0,"currency_code":"USD","in_stock":true},{"title":"16 Channel \/ 160mV","offer_id":50036334330093,"sku":"VOLTX-16-160MV","price":1759.0,"currency_code":"USD","in_stock":true},{"title":"16 Channel \/ 3.2V","offer_id":50036334362861,"sku":"VOLTX-16-3V","price":1759.0,"currency_code":"USD","in_stock":true},{"title":"16 Channel \/ 32V","offer_id":50036334395629,"sku":"VOLTX-16-32V","price":1759.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2586\/3536\/files\/1ed073ecaf5e982672f67d415ed1acbf.png?v=1780062475","url":"https:\/\/www.iothrifty.com\/products\/voltx-4-8-12-and-16-channel-dc-voltage-data-logger","provider":"IOThrifty","version":"1.0","type":"link"}