N1500-LC - Load Cell Panel Meter

Free Shipping! - USA Orders Over $75

Customer Reviews
N1500-LC - Load Cell Panel Meter
N1500-LC - Load Cell Panel Meter
N1500-LC - Load Cell Panel Meter
N1500-LC - Load Cell Panel Meter
N1500-LC - Load Cell Panel Meter

N1500-LC - Load Cell Panel Meter

Regular price $353.00 Sale SKU:N1500-LC-4R-RS485-24V
Contact IOThrifty for availability

  • Digital Panel Meter Designed for Weighing Systems with Load Cells
  • Accepts 4-20 mA, 0-20 mA, 0-50 mV, 0-20 mV, and -20 to 20 mV Inputs
  • 6-Digit LED Display for Process Value and Parameter Indication
  • 5 Vdc or 10 Vdc Load Cell Excitation Supply
  • Hold, Peak Hold, Tare, Zero Tare, and Automatic Zero Functions
  • Memory for Maximum and Minimum Values
  • Two Alarm Outputs Standard with Optional 3rd and 4th Alarm Relays
  • Optional 0-20 mA or 4-20 mA Process Variable Retransmission
  • Optional RS485 Modbus RTU Serial Communication
  • Front Panel Configuration with No Circuit Changes Required

The NOVUS N1500LC is a digital panel meter designed specifically for weighing systems using load cells. It provides a clear 6-digit LED display for measured values and programming parameters, making it well suited for industrial weighing, monitoring, and panel-mounted measurement applications.

The N1500LC supports a wide range of electrical input signals, including 4-20 mA, 0-20 mA, 0-50 mV, 0-20 mV, and -20 to 20 mV. Its configurable indication range allows the display to be set up for the application, while the built-in 5 Vdc or 10 Vdc auxiliary supply provides excitation power for compatible load cells.

Weighing and Load Cell Functions
The N1500LC includes functions commonly needed in scale and weighing applications, such as Tare, Zero Tare, Automatic Zero, Hold, and Peak Hold. It can also store maximum and minimum measured values, helping operators monitor process limits or capture peak weighing events.

Alarms and Output Options
The standard unit includes two alarm outputs, with optional configurations available for up to four alarm relays. Alarm functions include low alarm, high alarm, open sensor detection, and differential alarm modes. Optional process variable retransmission is available as a 0-20 mA or 4-20 mA analog output for sending the measured value to other control or monitoring equipment.

Communication and Configuration
Optional RS485 Modbus RTU communication allows the N1500LC to be integrated into industrial networks for remote monitoring and data acquisition. Configuration is performed through the front keypad, allowing input type, alarm behavior, display scaling, digital input functions, and other parameters to be programmed without changing the internal circuit.

 Downloads
N1500-LC Manual
Communcation Interface Guide

To Order click on the model no.(or scroll to the top of page and select your configuration) then click the ADD TO CART button
Model No. Configuration
N1500-LC-2R 2 Relays + 4-20 mA Retransmission, 100-240 Vac/dc Power
N1500-LC-4R-RS485 4 Relays + 4-20 mA Retransmission + RS485, 100-240 Vac/dc Power
N1500-LC-4R-RS485-24V 4 Relays + 4-20 mA Retransmission + RS485, 24 Vdc Power

 

SPECIFICATIONS

Dimensions: 48 x 96 x 92 mm (1/8 DIN)
Approximate Weight: 250 g
Panel Cut-out: 45 x 93 mm (+0.5 -0.0 mm)
Power Supply: 100 to 240 Vac/dc (±10 %), 50/60 Hz
Optional 24 V Power: 12 to 24 Vcc / 24 Vca (-10 % / +20%)
Maximum Consumption: 7.5 VA
Operating Temperature: 5 to 50 °C
Maximum Relative Humidity: 80 % up to 30 °C. For temperatures above 30 °C, decrease 3 % per °C.
Use: Indoor use; Installation category II, pollution degree 2; altitude < 2000 m


Input Types
Current: 0-20 mA, 4-20 mA
Voltage: 0-50 mV, 0-20 mV, -20 to 20 mV
Non-linear Inputs: c.4-20, c.0-20, c.50, c.-20, c.20 with customized linearization
Programmable Indication Range: -31000 to 31000, 0 to 60000, or 0 to 120000 with only even values
Internal Resolution: 128000 levels
Display Resolution: 62000 levels
Input Sample Rate: 15 samples per second
Accuracy: 0.2 % of span
Input Impedance 0-50 mV: >10 MΩ
Input Impedance 0-20 mA / 4-20 mA: 15 Ω (+2 Vdc @ 20 mA)


Analog Output: 0-20 mA or 4-20 mA, 550 Ω max.
Analog Output Resolution: 4000 levels, isolated, for control or retransmission of PV and SP
Relay Output ALM1 and ALM2: SPDT: 3 A / 240 Vac (3 A / 30 Vdc Res.)
Relay Output ALM3 and ALM4: SPST-NO: 1.5 A / 250 Vac (3 A / 30 Vdc Res.)
Auxiliary Voltage Supply: 5 or 10 Vdc, ±1 %, 35 mA


Serial Communication: Optional RS485 Modbus RTU
Connection: 2-wire RS485 connection with a master and up to 31 digital panel meters, addressable up to 247
Maximum Connection Distance: 1000 meters
Baud Rate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115600 bps
Data Bits: 8 with no parity or even parity
Stop Bits: 1
Response Start Time: Maximum 100 ms after receiving the command
Protocol: MODBUS RTU


Front Panel: IP65, polycarbonate UL94 V-2
Housing: IP20, ABS + PC UL94 V-0
Connections: Suitable for terminal type fork 6.3 mm
Starts Operation: 3 seconds after power-up
EMC: EN61326-1:1997 and EN61326-1/A1:1998
Safety: EN61010-1:1993 and EN61010-1/A2:1995