Learning/Articles

Free Shipping! - USA Orders Over $75

Customer Reviews

IOThrifty Blog

How to Chose the right Thermocouple

How to Chose the right Thermocouple

Choosing a thermocouple comes down to two questions: what are you measuring, and how hot or cold does it get? This guide covers sensor styles for air, surfaces and liquids, how to pick a junction, and when to use K, J, T or another type.

Hot Spot Monitoring with a Thermal Camera

Hot Spot Monitoring with a Thermal Camera
See the whole area, not just one point A hot spot is usually the first sign that something is off. A heated sheet has a cold zone that won't form r...

ISO 17025 Calibrated Thermocouples: A Buyer’s Guide

ISO 17025 Calibrated Thermocouples: A Buyer’s Guide
If an auditor, customer, or quality manager told you that you need an ISO 17025 calibrated thermocouple, this guide explains what that means and wh...

IOThrifty now offers ISO/IEC 17025 Thermocouple Calibration

IOThrifty now offers ISO/IEC 17025 Thermocouple Calibration

Buy your thermocouple and get it calibrated in one order. IOThrifty now offers 3-point thermocouple calibration, NIST-traceable or ISO/IEC 17025 accredited, at prices that won't break the budget, with standard or custom calibration points.

Why Thermal Cameras Matter in Metal Additive Manufacturing and Laser Processing

Why Thermal Cameras Matter in Metal Additive Manufacturing and Laser Processing

How short-wave thermal cameras measure melt pools in laser additive manufacturing, why emissivity matters for hot metal, and where the PI 08M fits.

Understanding Two-Wire (Loop-Powered) Transmitters

Understanding Two-Wire (Loop-Powered) Transmitters

Two-wire transmitters power themselves and send their signal over the same pair of wires. Learn how the 4-20 mA current loop works, why it became the industry standard, how to wire multiple devices in series, and how to calculate maximum cable length.

 

Introducing Dasberry Cloud

Introducing Dasberry Cloud

For years, great remote monitoring was only built for companies with the biggest budgets. So we built Dasberry Cloud: an easy, truly device agnostic IoT platform with dashboards, data logging, alerts and reporting for any MQTT device. A generous free plan, everything-included pricing, and a free perpetual license with every connected device we sell.

Wireless Control without a Computer, PLC or Pre-existing Wireless Network

Wireless Control without a Computer, PLC or Pre-existing Wireless Network

When traditional wired sensors aren’t practical, wireless industrial sensing can bridge the gap without the complexity of a full PLC system. In this article, IOThrifty walks through a real-world application where temperature and humidity had to be monitored on a moving machine using a wireless sensor, Modbus gateway, and relay controller. The result was a simple, self-contained control system with no Wi-Fi, PLC programming, or IT infrastructure required.

Monitoring Electrical Bus Bar Temperatures with Infrared Sensors

Monitoring  Electrical Bus Bar Temperatures with Infrared Sensors

Bus bars are the backbone of industrial power distribution, but their connection points are also one of the most common sources of failure. Loose connections, corrosion, and thermal cycling can create resistance that leads to dangerous hot spots, often long before any visible signs appear. By using non-contact infrared temperature sensors, maintenance teams can continuously monitor bus bar conditions, detect issues early, and prevent costly downtime or safety incidents.


How to Measure Asphalt Temperature During Road Paving

How to Measure Asphalt Temperature During Road Paving

Monitoring asphalt temperature at every stage of road paving, from the plant to final compaction, is essential to ensure a durable, long-lasting surface. This article explains how and when to measure temperature using infrared tools, with a special focus on the IOThrifty PyroCouple sensor as a smart solution for construction professionals.

Monitoring Coolant Flow in High-Density Liquid-Cooled Data Centers

Monitoring Coolant Flow in High-Density Liquid-Cooled Data Centers

Measuring flow in liquid-cooled data center racks is critical as power densities increase and traditional air cooling falls short. This comprehensive guide explains how coolant flow is monitored in direct-to-chip and rear-door heat exchanger systems, including equations, sensor technology tradeoffs, and BMS integration. It is written for engineers responsible for designing and operating modern, high-density data centers.

What Is a Signal Conditioner?

A signal conditioner is the critical link between sensors and control systems, transforming raw, noisy signals into clean, standardized data engineers can trust. From amplifying microvolt readings to isolating circuits and linearizing temperature inputs, it ensures accurate and safe measurements in demanding environments. In temperature control applications, devices like the TxRail-USB, TxIsoRail, and I4P from IOThrifty deliver reliable, noise-free 4–20 mA or 0–10 V outputs that keep industrial systems running smoothly.