Learning/Articles

Free Shipping! - USA Orders Over $75

Customer Reviews

IOThrifty Blog

How to Measure Asphalt Temperature During Road Paving

How to Measure Asphalt Temperature During Road Paving

Monitoring asphalt temperature at every stage of road paving, from the plant to final compaction, is essential to ensure a durable, long-lasting surface. This article explains how and when to measure temperature using infrared tools, with a special focus on the IOThrifty PyroCouple sensor as a smart solution for construction professionals.

Monitoring Coolant Flow in High-Density Liquid-Cooled Data Centers

Monitoring Coolant Flow in High-Density Liquid-Cooled Data Centers

Measuring flow in liquid-cooled data center racks is critical as power densities increase and traditional air cooling falls short. This comprehensive guide explains how coolant flow is monitored in direct-to-chip and rear-door heat exchanger systems, including equations, sensor technology tradeoffs, and BMS integration. It is written for engineers responsible for designing and operating modern, high-density data centers.

What Is a Signal Conditioner?

A signal conditioner is the critical link between sensors and control systems, transforming raw, noisy signals into clean, standardized data engineers can trust. From amplifying microvolt readings to isolating circuits and linearizing temperature inputs, it ensures accurate and safe measurements in demanding environments. In temperature control applications, devices like the TxRail-USB, TxIsoRail, and I4P from IOThrifty deliver reliable, noise-free 4–20 mA or 0–10 V outputs that keep industrial systems running smoothly.

How Glycol Concentration Affects Leak Detection in Data Center Cooling Loops

In liquid-cooled data centers, glycol keeps systems from freezing, but too much can make leak detection go blind. We tested how propylene glycol concentration affects conductive leak sensors and found that detection stops around 80%. See how your cooling loop compares.

Intro to Temperature Data Loggers

Intro to Temperature Data Loggers

Learn about the different types of temperature data loggers used across industries such as food, pharmaceuticals, HVAC, and manufacturing. Compare thermocouple, RTD, thermistor, and wireless models to choose the right logger for your monitoring needs.

Data Center Leak Detection and Monitoring for Liquid-Cooled Systems

Data Center Leak Detection and Monitoring for Liquid-Cooled Systems

High-density data centers are rapidly adopting liquid cooling technologies such as direct-to-chip cold plates and rear-door heat exchangers to manage racks drawing 15–30 kW or more. These systems often rely on propylene glycol mixtures in primary and secondary loops to transport heat safely and efficiently. However, introducing liquid to IT spaces introduces leak risk. Effective leak detection, integrated with a building management system (BMS) and tuned for water-glycol mixture, is now critical for uptime. Using IOThrifty solutions such as the LD1 Leak Detection System and LD Leak Detection Switch, engineers can deploy wide-area sensing, pinpoint leak location, and trigger immediate alarms to protect servers and maintain cooling continuity.

Wireless Temperature Sensors in Remote Industrial Sites

Wireless Temperature Sensors in Remote Industrial Sites

Discover how wireless temperature sensors, transmitters and data loggers improve remote industrial monitoring by enhancing accuracy, efficiency and long term performance tracking.

Are Data Loggers FDA 21 CFR Part 11 Compliant?

Are Data Loggers FDA 21 CFR Part 11 Compliant?

Data loggers including those measuring temperature, humidity, and thermocouple inputs can meet FDA 21 CFR Part 11 compliance when paired with validated software and documented procedures. It highlights key requirements such as audit trails, user authentication, electronic signatures, and links to official FDA resources while pointing readers to IOThrifty’s data logger collection.



Are Thermocouple Connectors Interchangeable Between Manufacturers?

Male and Female Connectors
Are Thermocouple Connectors Interchangeable Between Manufacturers? When sourcing thermocouple connectors, it's common to wonder whether a male conn...

Intro to the FieldLogger

Intro to the FieldLogger

Explore the FieldLogger, a powerful industrial data logger and data acquisition system with universal inputs, Modbus RTU, Ethernet, cloud connectivity, and more. Ideal for remote monitoring, process control, and industrial automation.

Infrared Temperature Sensors - The Importance of Field of View and Spot Size

Infrared Temperature Sensors - The Importance of Field of View and Spot Size

Field of view (FOV) and spot size are critical for accurate infrared temperature measurement. This guide explains how distance-to-spot (D:S) ratios affect sensor performance and why proper alignment and sizing matter when using IR sensors in industrial, HVAC, and research applications. Learn how to calculate spot size, avoid background interference, and improve temperature accuracy when measuring small or distant targets.

Managing Heat Index in Industrial Facilities

Managing Heat Index in Industrial Facilities

In this article, we break down what the heat index is, why it matters in industrial settings, how to measure it (even indoors with hot equipment), and what solutions (like sensor-based monitors) can help. We’ll also touch on new OSHA rules that make heat hazard management a must for employers.