  • An excellent solution for most industrial fluid leak detection applications including Data Centers and Server Rooms
  • Visual and audible alerts with immediate relay control
  • Connectivity to PLC's, BMS and SCADA systems via Modbus
  • Cables with patch cords across two channels Allow for a large coverage area (up to 200 meters - 100 meter per channel). Sold separately.
  • Accurately displays leak location on LCD screen within 5 seconds of detection
  • Supports WiFi/4G/RJ45 ethernet connections for versatile Networking
  • Real-Time alerts via app, emails, calls/SMS, and HTTP
  • Data available via cloud platform
  • Real-Time alerts on the working status of the device or cables
  • Fire-resistant and wear-resistant materials

The LD1 is an advanced leakage and flood detection system designed to enhance safety and efficiency in various environments. It features a highly sensitive, fire-resistant, and robust water detection cable that triggers an immediate visual and audible alarm upon detection of water.

With the capability to connect to the cloud platform via WiFi, 4G, or RJ45 Ethernet, the LD1 ensures that all data is accessible remotely. This allows users to receive real-time alerts and manage settings directly from their smartphones, tablets, or computers. Built for industrial settings, the LD1 delivers peace of mind through continuous monitoring and immediate alerts.

Ideal for Data Center and Server Room Applications
The LD1 is engineered for critical environments such as data centers and server rooms, where even a small leak can cause costly downtime. Although designed for conductive liquids, it has been successfully tested with propylene glycol and water mixtures up to 75 percent propylene glycol, exceeding the concentration used in most cooling loops. This makes it ideal for high density rack systems, including direct to chip liquid cooling and rear door heat exchangers. With dual detection channels covering up to 200 meters, the LD1 monitors beneath raised floors and along coolant lines for rapid, pinpoint leak detection that protects vital infrastructure.

Visual and Audible Alerts with Immediate Relay Control
When a leak is detected, the LD1 instantly activates bright visual indicators and an audible alarm to draw attention. Its relay output provides a 12V signal at up to 100 mA, which can directly trigger pumps, solenoid valves, or external alarms for immediate response. This built-in control output allows the LD1 to automatically initiate protective actions the moment a leak occurs, reducing downtime and preventing damage.

Integration with PLC, BMS, and SCADA Systems
The LD1 communicates using the RS485 Modbus protocol, allowing seamless integration with PLCs, building management systems, and SCADA platforms. This connectivity brings leak status and environmental data into your existing automation for centralized visibility and faster response.

Accurate Leak Location Display in Under 5 Seconds
The LD1 pinpoints the leak and displays its distance from the device, shown in either feet or meters, within five seconds of detection. This precise feedback helps teams quickly locate and fix the source, minimizing downtime and preventing damage.

Cloud-Based Data, Reporting, and Alerts
The LD1 connects to a secure cloud platform where users can view real-time and historical leak data from any web browser or mobile device. The free cloud plan includes data logging, remote access, and customizable alerts by app or email, with optional SMS and voice notifications. Users can analyze trends, export reports, and integrate data through an open API for advanced monitoring or automation.

Network and Connection Flexibility
The LD1 model variations cater to different networking needs, including exclusive models with WiFi, Ethernet, or 4G connectivity. This ensures that whatever your setup, there is a compatible LD1 model ready to integrate seamlessly.

 

.

To Order the model below click on the link or scroll to the top of the page then click on ADD TO CART button
PART NUMBERS Connectivity
LD1-A2LIn Stock LD1 Leak Detection System with WiFi Connection (No Cable Included)
LD1-AETH2LIn Stock LD1 Leak Detection System with WiFi and Ethernet Connection (No Cable Included)
LD1-AL4G2L LD1 Leak Detection System with WiFi and Ethernet Connection 2G or 3G or 4G (includes SIM card - see details on cellular plans and pricing - No Cable Included)
UB-LD-N1-3M 3 meter leak detection cable
UB-LD-N1-10M 10 meter leak detection cable
UB-LDPC-N1-5M 5 meter patch cord
UB-LDPC-N1-10M 10 meter patch cord
UB-RS485 Cable for supporting RS485 or Modbus communication
UB-RLY Cable for supporting external relay

 Downloads
User Guide
Modbus Guide 


 Videos

 

SPECIFICATIONS
Models: LD1-A2L (WiFi), LD1-AETH2L (WiFi and Ethernet), LD1-AL4G2L (WiFi and Cellular)
Non-corrosive Conductive Liquid Detection: Up to 100 meters per channel
Accuracy: ±0.5 meters
Response Time: <5 seconds
Network: 2.4 GHz WiFi (channels 1 to 13), 4G, RJ45 Ethernet (model dependent)
Output Signal: RS485, Relay output (DC 12V, ≤ 100 mA)
Power Supply: DC 12V or 2 A
External Probes Supported: Multiple leak detection cables in series, 1 x smoke sensor, 1 x TH30S-B temperature and humidity probe